m+Medelevator.RU
← Поиск публикаций
Journal of electrocardiology · 2026

Comparison between measured and synthesized posterior lead electrocardiograms during percutaneous coronary intervention-induced myocardial ischemia.

СтатьяСравнительное исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Setoguchi Toshiki, Matsumoto Naoya, Matsunaga Yuro, Iwata Ryotaro, Otsuka Naoto, Monden Masaki, Fujito Hidesato, Yagi Tsukasa, Matsumoto Michiaki, Suzuki Yasuyuki, Washio Takehiko, Fukamachi Daisuke, Yokoyama Katsuaki, Okumura Yasuo, Yamauchi Tsuyoshi

Аннотация

BACKGROUND: Posterior/inferolateral myocardial ischemia is frequently underrecognized on standard 12‑lead electrocardiography (ECG). Synthesized posterior leads derived from the standard 12‑lead ECG have been proposed as an alternative to directly measured posterior leads; however, their accuracy under controlled ischemic conditions has not been fully validated.

METHODS: We prospectively enrolled 26 consecutive patients undergoing percutaneous coronary intervention (PCI) in whom simultaneously recorded measured and synthesized posterior lead ECGs (V7-V9) were obtained during balloon-induced myocardial ischemia. ST-segment deviation was measured at the ST junction (STJ), 40 ms (ST1), and 80 ms (ST2) thereafter. Agreement between measured and synthesized posterior leads was assessed using Pearson correlation and Bland-Altman analyses. As an exploratory patient-level analysis, diagnostic performance was compared with reciprocal anterior ST-segment depression (V1-V4).

RESULTS: Strong correlations were observed between measured and synthesized posterior lead ST-segment deviations (V7: r = 0.89; V8: r = 0.86; V9: r = 0.83; all P < 0.001). Bland-Altman analysis demonstrated minimal systematic bias (within ±0.004 mV) and narrow limits of agreement. Synthesized posterior leads showed higher diagnostic performance than reciprocal anterior ST-segment depression (AUC 0.917 vs. 0.708), although the difference was not statistically significant (DeLong test, P = 0.197). Using a 0.05 mV threshold, synthesized posterior leads demonstrated 83.3% sensitivity, 100% specificity, and 96.2% overall accuracy.

CONCLUSIONS: Synthesized posterior leads closely reproduced measured posterior lead ST-segment deviations during percutaneous coronary intervention (PCI)-induced myocardial ischemia, supporting the technical validity of posterior lead reconstruction. Larger prospective studies are warranted to determine whether synthesized posterior leads provide incremental diagnostic value beyond careful interpretation of the standard 12‑lead ECG.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты