Analysis of the correlation between biomechanical properties and corneal densitometry in myopic eyes.

Zheng Yuwei, Xue Chao, Wang Jing, Chen Xuan, Wang Xiaohui, Wang Yan

СтатьяПеревод пока не подготовлен

Аннотация

Background

To investigate the correlation between corneal biomechanical characteristics (in vitro and in vivo) and corneal densitometry in myopia.

Methods

The Pentacam (Oculus, Wetzlar, Germany) corneal densitometry (CD) and Corvis ST (Oculus, Wetzlar, Germany) exams were conducted prior to surgery for myopic patients who were intended to undergo small-incision lenticule extraction (SMILE). CD values (grayscale units, GSUs), and in vivo biomechanical parameters were obtained. The stromal lenticule was subjected to a uniaxial tensile test to obtain the elastic modulus E in vitro. We exam the correlations among in vivo, in vitro biomechanical characteristics and CD values.

Results

In this study, 37 myopic patients (63 eyes) were included. The mean age of participants was 25.14 ± 6.74 years (range:16-39 years). The mean CD values of the total cornea, anterior layer, intermediate layer, posterior layer, 0-2 mm region and 2-6 mm region were 15.03 ± 1.23 GSU, 20.35 ± 1.98 GSU, 11.76 ± 1.01 GSU, 10.95 ± 0.83 GSU, 15.57 ± 1.12 GSU and 11.94 ± 1.77 GSU, respectively. Elastic modulus E (in vitro biomechanical indicator) was negatively correlated with intermediate layer CD (r = -0.35, p = 0.01) and 2-6 mm region CD (r = -0.39, p = 0.00). A negative correlation was also found between 0-2 mm central region CD and in vivo biomechanical indicator SP-HC (r = -0.29, p = 0.02).

Conclusion

In myopic patients, densitometry is negatively correlated with biomechanical properties both in vivo and in vitro. With an increase in CD, the cornea deformed more easily.

Для цитирования: Zheng Yuwei, Xue Chao, Wang Jing, Chen Xuan, Wang Xiaohui, Wang Yan. Analysis of the correlation between biomechanical properties and corneal densitometry in myopic eyes.. Frontiers in bioengineering and biotechnology. 2023. DOI: 10.3389/fbioe.2023.1182372.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.