MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ajo.2023.04.008

Медицинская библиотека · American journal of ophthalmology · 2023

Deep Learning-Based Estimation of Implantable Collamer Lens Vault Using Optical Coherence Tomography.

Assaf Jad F, Reinstein Dan Z, Zakka Cyril, Arbelaez Juan G, Boufadel Peter, Choufani Mathieu, Archer Timothy, Ibrahim Perla, Awwad Shady T

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To develop and validate a deep learning neural network for automated measurement of implantable collamer lens (ICL) vault using anterior segment optical coherence tomography (AS-OCT).

DESIGN

Cross-sectional retrospective study.

METHODS

A total of 2647 AS-OCT scans were used from 139 eyes of 82 subjects who underwent ICL surgery in 3 different centers. Using transfer learning, a deep learning network was trained and validated for estimating the ICL vault on OCT. A trained operator separately reviewed all OCT scans and measured the central vault using a built-in caliper tool. The model was then separately tested on 191 scans. A Bland-Altman plot was constructed and the mean absolute percentage error (MAPE), mean absolute error (MAE), root mean squared error (RMSE), Pearson correlation coefficient (r), and determination coefficient (R2) were calculated to evaluate the strength and validity of the model.

RESULTS

On the test set, the model achieved a MAPE of 3.42%, an MAE of 15.82 µm, a RMSE of 18.85 µm, a Pearson correlation coefficient r of +0.98 (P < .00001), and a coefficient of determination R2 of +0.96. There was no significant difference between the vaults of the test set labeled by the technician vs those estimated by the model: 478 ± 95 µm vs 475 ± 97 µm, respectively, P = .064).

CONCLUSIONS

Using transfer learning, our deep learning neural network was able to accurately compute the ICL vault from AS-OCT scans, overcoming the limitations of an imbalanced data set and limited training data. Such an algorithm can assist the postoperative assessment in ICL surgery.

Для цитирования: Assaf Jad F, Reinstein Dan Z, Zakka Cyril, Arbelaez Juan G, Boufadel Peter, Choufani Mathieu, Archer Timothy, Ibrahim Perla, Awwad Shady T. Deep Learning-Based Estimation of Implantable Collamer Lens Vault Using Optical Coherence Tomography.. American journal of ophthalmology. 2023. DOI: 10.1016/j.ajo.2023.04.008.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.