MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00417-014-2737-9

Медицинская библиотека · Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie · 2014

The effect of posterior corneal flat meridian and astigmatism amount on the total corneal astigmatism estimated from anterior corneal measurements.

Eom Youngsub, Kang Su-Yeon, Kim Hyo Myung, Song Jong Suk

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

To evaluate the effects of posterior corneal astigmatism and the absolute flat meridian difference between anterior and posterior corneal surfaces (AMDAnt-Post) on the estimation of total corneal astigmatism using anterior corneal measurements (simulated keratometry [K]).

METHODS

Ninety-nine eyes of 99 healthy participants were enrolled. Anterior, posterior, and total mean corneal power, cylinder power, flat meridian, and vector components J0, and J45 measured by a dual Scheimpflug camera were analyzed. The correlation between the posterior corneal cylinder power, AMDAnt-Post, and the difference in the cylinder power between simulated K and total cornea (cylinder power differenceSimK-Tot) were evaluated.

RESULTS

The cylinder power differenceSimK-Tot was positively correlated with the posterior corneal cylinder power (rho = 0.704 and P < 0.001) and negatively correlated with AMDAnt-Post (rho = -0.717 and P < 0.001). In the multivariate linear regression analysis, anterior corneal J0 was strongly associated with the posterior corneal cylinder power and the AMDAnt-Post. When corneal J0 had a positive value, the cylinder power of simulated K tended to be larger than the total corneal cylinder power. In comparison, the opposite trend was presented in eyes with negative anterior corneal J0. When anterior corneal J0 was larger than 1.0 or smaller than -0.9, the errors from estimating the total corneal cylinder power using anterior corneal measurements tended to be larger than 0.25 D.

CONCLUSION

Posterior corneal astigmatism should be considered for more accurate corneal astigmatism predictions, especially in eyes with anterior corneal astigmatism greater than 2.0 D of with-the-rule astigmatism or greater than 1.8 D of against-the-rule astigmatism.

Для цитирования: Eom Youngsub, Kang Su-Yeon, Kim Hyo Myung, Song Jong Suk. The effect of posterior corneal flat meridian and astigmatism amount on the total corneal astigmatism estimated from anterior corneal measurements.. Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie. 2014. DOI: 10.1007/s00417-014-2737-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.