m+Medelevator.RU
← Поиск публикаций
Journal of cataract and refractive surgery · 2014

Rotational performance and corneal astigmatism correction during cataract surgery: aspheric toric intraocular lens versus aspheric nontoric intraocular lens with opposite clear corneal incision.

Сравнительное исследованиеСтатьяРандомизированное исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Maedel Sophie, Hirnschall Nino, Chen Yen-An, Findl Oliver

Аннотация

PURPOSE: To compare the astigmatism-reducing effect of an aspheric toric intraocular lens (IOL) and an aspheric nontoric IOL with an opposite clear corneal incision (OCCI) in cataract surgery.

SETTING: Vienna Institute for Research in Ocular Surgery, Hanusch Hospital, Vienna, Austria.

DESIGN: Prospective randomized clinical study.

METHODS: Patients with low to moderate corneal astigmatism scheduled for cataract surgery received an aspheric toric IOL (Lentis L-312T) or an aspheric nontoric IOL (Lentis L-312) combined with an OCCI. Keratometry and corneal tomography were performed 1 hour, 1 week, 3 months and 9 months postoperatively. Postoperative residual astigmatism was measured using an autorefractor. Rotational toric IOL stability was analyzed using retroillumination photography.

RESULTS: Fifty-five patients were included. Three months postoperatively, the mean reduction in corneal astigmatism was 0.67 diopter (D) ± 0.58 (SD) in the toric group and 0.18 ± 0.52 D in the nontoric-OCCI group. The mean uncorrected distance visual acuity was 0.29 ± 0.30 logMAR and 0.09 ± 0.18 logMAR, respectively (P=.02). The mean refractive astigmatism was 1.02 ± 0.54 D and 0.68 ± 0.52 D, respectively (P=.05). One hour, 3 months, and 9 months postoperatively, the mean absolute IOL misalignment of toric IOLs was 4.99 ± 4.66 degrees, 13.59 ± 11.29 degrees, and 19.90 ± 14.48 degrees, respectively.

CONCLUSIONS: The toric IOL tended to rotate significantly postoperatively. Visual acuity was good in both groups. Residual refractive cylinder was significantly lower in the toric IOL group.

FINANCIAL DISCLOSURE: No author has a financial or proprietary interest in any material or method mentioned.