Korean journal of ophthalmology : KJO · 2014
Comparison of surgically-induced astigmatism after combined phacoemulsification and 23-gauge vitrectomy: 2.2-mm vs. 2.75-mm cataract surgery.
Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Kim Yong-Kyu, Kim Yong Woo, Woo Se Joon, Park Kyu Hyung
Аннотация
PURPOSE: The 2.2-mm microincision cataract surgery and small-gauge vitrectomy system is known to result in less surgically-induced astigmatism (SIA) in comparison to conventional surgical methods. We compared the amounts of SIA after combined phacoemulsification and 23-gauge transconjunctival sutureless vitrectomy (23G-TSV) using the 2.2-mm microincision and 2.75-mm standard incision methods.
METHODS: We studied 59 patients (61 eyes) who underwent combined phacoemulsification and 23G-TSV from November 2008 to September 2012. Twenty-eight patients (28 eyes) underwent 2.2-mm microincision coaxial phacoemulsification, and 31 patients (33 eyes) underwent 2.75-mm standard incision phacoemulsification. SIA was evaluated using Naeser's polar method with the simulated keratometric values obtained from corneal topography. Preoperative and 1-week and 1-month postoperative KP (Naeser's polar value along the specific axis) and ΔKP values were compared between the 2.2-mm microincision and 2.75-mm standard incision groups.
RESULTS: One week after surgery, both groups exhibited similar amounts of SIA (-ΔKP[120], 0.40 ± 0.41 vs. 0.51 ± 0.56 diopters [D]; p = 0.390). One month after surgery, however, the amount of SIA was significantly smaller in the 2.2-mm microincision group as compared to the 2.75-mm standard incision group (-ΔKP[120], 0.31 ± 0.54 vs. 0.56 ± 0.42 D; p = 0.045).
CONCLUSIONS: In combined phacoemulsification with 23G-TSV, 2.2-mm microincision coaxial phacoemulsification induces less SIA than does 2.75-mm standard coaxial phacoemulsification.
METHODS: We studied 59 patients (61 eyes) who underwent combined phacoemulsification and 23G-TSV from November 2008 to September 2012. Twenty-eight patients (28 eyes) underwent 2.2-mm microincision coaxial phacoemulsification, and 31 patients (33 eyes) underwent 2.75-mm standard incision phacoemulsification. SIA was evaluated using Naeser's polar method with the simulated keratometric values obtained from corneal topography. Preoperative and 1-week and 1-month postoperative KP (Naeser's polar value along the specific axis) and ΔKP values were compared between the 2.2-mm microincision and 2.75-mm standard incision groups.
RESULTS: One week after surgery, both groups exhibited similar amounts of SIA (-ΔKP[120], 0.40 ± 0.41 vs. 0.51 ± 0.56 diopters [D]; p = 0.390). One month after surgery, however, the amount of SIA was significantly smaller in the 2.2-mm microincision group as compared to the 2.75-mm standard incision group (-ΔKP[120], 0.31 ± 0.54 vs. 0.56 ± 0.42 D; p = 0.045).
CONCLUSIONS: In combined phacoemulsification with 23G-TSV, 2.2-mm microincision coaxial phacoemulsification induces less SIA than does 2.75-mm standard coaxial phacoemulsification.