m+Medelevator.RU
← Поиск публикаций
Allergy · 2006

Basophil allergen threshold sensitivity: a useful approach to anti-IgE treatment efficacy evaluation.

Сравнительное исследованиеСтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Nopp A, Johansson S G O, Ankerst J, Bylin G, Cardell L O, Grönneberg R, Irander K, Palmqvist M, Oman H

Аннотация

BACKGROUND: Monitoring of the allergen sensitivity of a patient is most important for optimal patient care and a basic prerequisite for immunomodulating treatment. The objective of this study was to investigate how basophil allergen sensitivity can be applied in the monitoring of anti-immunoglobulin E (IgE) treatment.

METHODS: Basophils from timothy grass pollen allergic patients were, by flow cytometry, analysed for allergen threshold sensitivity (CD-sens) by measuring CD63 up-regulation on CD203c-identified basophils. The results were compared with maximal percentage CD63 up-regulation at one allergen dose (CD-max), skin prick test end-point allergen titration, (SPT-sens), nasal provocation titration tests (nasal provocation titre) and serum IgE and IgE antibody concentrations.

RESULTS: There was a significant correlation (r = 0.50, P = 0.01) between CD-sens and SPT-sens, CD-sens and the IgE antibody concentration in percentage of 'total IgE' (relative IgE antibody concentration) (r = 0.72, P < 0.001) as well as between CD-sens and nasal provocation titre (r = 0.54, P < 0.05) but, in contrast, CD-max did not correlate with any of the sensitization parameters, i.e. SPT-sens, nasal provocation titre, absolute and relative IgE antibody concentration or CD-sens. CD-sens could be used to monitor omalizumab treatment efficacy while, based on CD-max, four of seven symptom-free patients on omalizumab would have been classified as having ongoing allergy.

CONCLUSIONS: CD-sens seems to be very useful for the determination of a patient's allergen sensitivity and should be evaluated for the measurement and monitoring of anti-IgE treatment efficacy. CD-max, the conventional approach to basophil allergen challenge, which mirrors cell reactivity, gives incorrect information.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты