MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/s1051-0443(94)71626-2

Медицинская библиотека · Journal of vascular and interventional radiology : JVIR · 1994

Preliminary clinical experience with the Gunther temporary inferior vena cava filter.

Millward S F, Bormanis J, Burbridge B E, Markman S J, Peterson R A

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: The authors describe their preliminary clinical experience with the Gunther temporary inferior vena cava (IVC) filter.

PATIENTS AND

METHODS

Seven women and 10 men, mean age 52 years (range, 19-85 years), were treated with the temporary IVC filter. Indications for filter placement were pulmonary embolism (PE) in four patients and iliofemoral deep venous thrombosis in six. In these patients anticoagulation was contraindicated because of planned major surgery. Filters were placed in four patients following massive PE and in three for prophylaxis following cranial trauma. Four patients had underlying malignant disease. Filters were introduced through the right common femoral vein in 14 patients, the left common femoral vein in two, and the left internal jugular vein in one.

RESULTS

No patient developed recurrent PE with the filter in place. All filters were removed without complication 3-14 days (mean, 7 days) after placement. Two of the patients with underlying malignant disease required placement of a permanent filter. Two patients developed IVC thrombosis with the filter in place, and both developed recurrent PE after filter removal. Two patients developed insertion vein thrombosis. One patient developed a bleeding disorder that caused a massive hematoma at the insertion vein site, which may have contributed to her death.

CONCLUSION

The Gunther temporary filter can be used in selected patients; however, patients with underlying malignant disease may be more appropriately treated with a permanent filter. The temporary filter does not appear to reduce the rate of insertion vein and IVC thrombosis.

Для цитирования: Millward S F, Bormanis J, Burbridge B E, Markman S J, Peterson R A. Preliminary clinical experience with the Gunther temporary inferior vena cava filter.. Journal of vascular and interventional radiology : JVIR. 1994. DOI: 10.1016/s1051-0443(94)71626-2.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.