MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1067/mva.1991.29913

Медицинская библиотека · Journal of vascular surgery · 1991

Results of a multicenter study of the modified hook-titanium Greenfield filter.

Greenfield L J, Cho K J, Proctor M, Bonn J, Bookstein J J, Castaneda-Zuniga W R, Cutler B, Ferris E J, Keller F, McCowan T

Клиническое исследованиеСтатьяМногоцентровое исследованиеПеревод пока не подготовлен

Аннотация

Initial efforts to modify the stainless steel Greenfield filter for percutaneous insertion led to development of a titanium Greenfield filter, which could be inserted by use of a 12F carrier. This device functioned well as a filter but had an unacceptable 30% rate of migration, tilting, and penetration. Therefore a titanium Greenfield filter with modified hooks was developed and has been tested in 186 patients at 10 institutions. Successful placement occurred in 181 (97%); placement of the remainder was precluded by unfavorable anatomy. A contraindication to anticoagulation was the most frequent indication for insertion (75%). All but two were inserted percutaneously, predominantly via the right femoral vein (70%). Initial incomplete opening was seen in four patients (2%), which was corrected by guide wire manipulation and asymmetry of the legs in 10 (5.4%). Insertion site hematoma occurred in one patient, and apical penetration of the cava during insertion occurred in a second patient. Both events were without sequelae. Follow-up examinations were performed at 30 days at which time 35 deaths had occurred. Recurrent embolism was suspected in six patients (3%) and two of three deaths were confirmed by autopsy. Filter movement greater than 9 mm was seen in 13 patients, (11%) and increase in base diameter greater than or equal to 5 mm was seen in 17 patients (14%). CT scanning showed evidence of caval penetration in only one patient (0.8%). Insertion site venous thrombosis was seen in 4/46 (8.7%) patients screened. The modified hook titanium Greenfield filter is inserted percutaneously or operatively through a sheath, eliminating concern for misplacement from premature discharge.(ABSTRACT TRUNCATED AT 250 WORDS)

Для цитирования: Greenfield L J, Cho K J, Proctor M, Bonn J, Bookstein J J, Castaneda-Zuniga W R, Cutler B, Ferris E J, Keller F, McCowan T. Results of a multicenter study of the modified hook-titanium Greenfield filter.. Journal of vascular surgery. 1991. DOI: 10.1067/mva.1991.29913.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.