Journal of the American College of Cardiology · 1987

Pathologic findings related to the lead system and repeated defibrillations in patients with the automatic implantable cardioverter-defibrillator.

СтатьяПоддержка службы здравоохранения СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Singer I, Hutchins G M, Mirowski M, Mower M M, Veltri E P, Guarnieri T, Griffith L S, Watkins L, Juanteguy J, Fisher S

Аннотация

The purpose of the present study was to examine at autopsy the effect of multiple defibrillations on the myocardium and the pathologic consequences of short- and long-term placement of the intravascular and interpericardial leads of the automatic implantable cardioverter-defibrillator. Twenty-five patients were examined at autopsy; 8 of them underwent lead implantation only and 17 received both leads and the automatic implantable cardioverter-defibrillator. Twelve patients (48%) died of ventricular tachycardia or ventricular fibrillation; seven (28%) died of other causes. Acute pericarditis occurred in all patients, resulting in a localized, progressive fibrosis around the apical patch lead without giving rise to pericardial restriction. Thrombus formation was associated with the superior vena cava spring electrode in four patients (17%) and the right ventricular rate-sensing electrode in one patient (4%). Asymptomatic pulmonary emboli occurred in two patients (8%). In one patient who underwent defibrillation 59 times, superior vena cava changes consisted of vein wall destruction, fibrosis and thrombus formation. Pathologic changes under the apical patch related to defibrillation were observed in seven patients; two of these had fewer than 5 defibrillations, one had 8 defibrillations and four had 21 to 74 defibrillations. These changes consisted of contraction band necrosis in four patients, vacuolar cytoplasmic clearing and loss of myocytes confined to the myocardium under the patch electrode in five patients who had multiple defibrillations. The observed pathologic changes were estimated to affect less than 2% of the total myocardial mass. Thus, the automatic implantable cardioverter-defibrillator lead system and multiple defibrillations result in localized myocardial injury confined to the tissue under the patch electrode.(ABSTRACT TRUNCATED AT 250 WORDS)

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты