MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1164/rccm.202406-1170oc

Медицинская библиотека · American journal of respiratory and critical care medicine · 2025

Effects of Continuous Positive Airway Pressure on Neuroimaging Biomarkers and Cognition in Adult Obstructive Sleep Apnea: A Randomized Controlled Trial.

Xu Huajun, Liu Yupu, Li Chenyang, Li Xinyi, Shen Li, Wang Hui, Liu Feng, Zou Juanjuan, Xia Yunyan, Huang Weijun, Liu Yuenan, Gao Zhenfei, Fu Yiqun, Wang Fan, Huang Shujian, Song Zhiyuan, Song Fan, Gao Yiqing, Peng Yu, Zou Jianyin, Zhu Huaming, Liu Suru, Li Linpeng, Zhu Xiaoyue, Xiong Yuanping, Hu Yuli, Yang Jiaxin, Li Yuehua, Gao Feng, Guo Qihao, Huang Hengye, Zhang Weituo, Li Jiping, Chen Yanqing, Dong Pin, Yang Jun, Lv Jingrong, Wang Peihua, Sun Yiyuan, Qian Biyun, Yaffe Kristine, Guan Jian, Yi Hongliang, Leng Yue, Yin Shankai

СтатьяРандомизированное исследованиеМногоцентровое исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

Rationale: Obstructive sleep apnea (OSA) is associated with cognitive impairment. The effects of continuous positive airway pressure (CPAP) on neuroimaging biomarkers and cognitive performance among middle-aged patients with OSA and normal cognition remain unclear.

Objectives

To investigate the effects of CPAP therapy over 12 months on neuroimaging biomarkers and cognitive performance.

Methods

In this multicenter, randomized clinical trial, we randomly assigned 148 participants with normal cognition and an apnea-hypopnea index ⩾15/h into two groups: patients receiving CPAP with best supportive care (BSC); and patients receiving BSC alone. The primary endpoint was Montreal Cognitive Assessment (MoCA) score at 6 months after enrollment. The secondary endpoints were intranetwork functional connectivity (FC) of default mode network (DMN) and cortical thickness assessed by functional and structural magnetic resonance imaging, other neuroimaging biomarkers, and neurobehavioral tests. Measurements and Main

Results

Between 2017 and 2021, 148 patients were recruited from five hospitals. Linear mixed models showed that there was no significant difference in MoCA scores at 6 months between the CPAP and BSC groups (difference, -0.04; 95% confidence interval [CI], -0.72 to 0.65; P = 0.91). However, there were significant differences in the FC of DMN (difference, -13.73; 95% CI, -23.40 to -4.06; P = 0.01) and cortical thickness (difference, -0.06 mm; 95% CI, -0.10 to -0.01 mm; P = 0.02) between CPAP and BSC groups at 6 months after treatment. No serious adverse events occurred.

Conclusions

CPAP improved cortical thickness and FC of DMN, suggesting that patients with OSA may recover from brain atrophic processes after CPAP treatment. However, no improvement in MoCA was found. Clinical trial registered with www.clinicaltrials.gov (NCT02886156).

Для цитирования: Xu Huajun, Liu Yupu, Li Chenyang, Li Xinyi, Shen Li, Wang Hui, Liu Feng, Zou Juanjuan, Xia Yunyan, Huang Weijun, Liu Yuenan, Gao Zhenfei, Fu Yiqun, Wang Fan, Huang Shujian, Song Zhiyuan, Song Fan, Gao Yiqing, Peng Yu, Zou Jianyin, Zhu Huaming, Liu Suru, Li Linpeng, Zhu Xiaoyue, Xiong Yuanping, Hu Yuli, Yang Jiaxin, Li Yuehua, Gao Feng, Guo Qihao, Huang Hengye, Zhang Weituo, Li Jiping, Chen Yanqing, Dong Pin, Yang Jun, Lv Jingrong, Wang Peihua, Sun Yiyuan, Qian Biyun, Yaffe Kristine, Guan Jian, Yi Hongliang, Leng Yue, Yin Shankai. Effects of Continuous Positive Airway Pressure on Neuroimaging Biomarkers and Cognition in Adult Obstructive Sleep Apnea: A Randomized Controlled Trial.. American journal of respiratory and critical care medicine. 2025. DOI: 10.1164/rccm.202406-1170oc.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.