MedElevator Войти в исследования
← Поиск публикаций

DOI 10.4103/ua.ua_73_23

Медицинская библиотека · Urology annals · 2023

The use of artificial intelligence and deep learning reconstruction in urological computed tomography: Dose reduction at ghost level.

Rauf Abdul, Javed Saqib, Chandrasekar Bhargavi, Miah Saiful, Lyttle Margaret, Siraj Mamoon, Mukherjee Rono, McLeavy Christopher M, Alaaraj Hazem, Hawkins Richard

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

The objective of the study is to demonstrate that with the use of artificial intelligence (AI) in computed tomography (CT), radiation doses of CT kidney-ureter-bladder (KUB) and CT urogram (CTU) can be reduced to less than that of X-ray KUB and CT KUB, respectively, while maintaining the good image quality.

MATERIALS AND

METHODS

We reviewed all CT KUBs (n = 121) performed in September 2019 and all CTUs (n = 74) performed in December 2019 at our institution. The dose length product (DLP) of all CT KUBs and each individual phase of CTU were recorded. DLP of each scan done with new scanner (Canon Aquilion One Genesis with AiCE [CAOG]) which uses AI and deep learning reconstruction (DLR) were compared against traditional non-AI scanner (GE OPTIMA 660 [GEO-660]). We also compared DLPs of both scanners against the United Kingdom, National Diagnostic Reference Levels (NDRL) for CT.

RESULTS

One hundred and twenty-one patient's CT KUBs and 74 patient's CTUs were reviewed. For CT KUB group, the mean DLP of 81/121 scans done using AI/DLR scanner (CAOG) was 77.8 mGy cm (1.16 mSv), while the mean DLP of 40/121 CT KUB done with GEO-660 was 317.1 mGy cm (4.75 mSv). For CTU group, the mean DLP for 46/74 scans done using AI/DLR scanner (CAOG) was 401.9 mGy cm (6 mSv), compared to mean DLP of 1352.6 mGy cm (20.2 mSv) from GEO-660.

CONCLUSION

We propose that CT scanners using AI/DLR method have the potential of reducing radiation doses of CT KUB and CTU to such an extent that it heralds the extinction of plain film XR KUB for follow-up of urinary tract stones. To the best of our knowledge, this is the first study comparing CT KUB and CTU doses from new scanners utilizing AI/DLR technology with traditional scanners using hybrid iterative reconstruction technology. Moreover, we have shown that this technology can markedly reduce the cumulative radiation burden in all urological patients undergoing CT examinations, whether this is CT KUB or CTU.

Для цитирования: Rauf Abdul, Javed Saqib, Chandrasekar Bhargavi, Miah Saiful, Lyttle Margaret, Siraj Mamoon, Mukherjee Rono, McLeavy Christopher M, Alaaraj Hazem, Hawkins Richard. The use of artificial intelligence and deep learning reconstruction in urological computed tomography: Dose reduction at ghost level.. Urology annals. 2023. DOI: 10.4103/ua.ua_73_23.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.