m+Medelevator.RU
← Поиск публикаций
The journal of advanced prosthodontics · 2026

In vivo evaluation of a 3D-printable polyurethane-acrylate soft denture liner.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Lee Dong-Joon, Park Jang-Hyun, Park Jaehan

Аннотация

PURPOSE: The purpose of this study was to evaluate the in vivo biological response of a newly developed 3D-printable polyurethane-acrylate-based soft denture liner (SDL) following direct contact with oral mucosa, focusing on cytocompatibility, epithelial integrity, and inflammatory responses.

MATERIALS AND METHODS: A polyurethane-acrylate SDL formulation optimized for additive manufacturing was fabricated using digital light processing (DLP) 3D printing. Cytotoxicity was assessed in vitro using L929 fibroblasts according to ISO 10993-5 guidelines through microscopic observation and MTT assays. For in vivo evaluation, plate-shaped SDL specimens were applied to the buccal mucosa of Sprague-Dawley rats, with sutured sham controls. Animals were sacrificed at 24 h (day 1) and 72 h (day 3). Histological assessment was performed using hematoxylin and eosin staining, while epithelial integrity and differentiation were evaluated by immunohistochemistry for E-cadherin and pan-keratin. Inflammatory and collagen-related gene expression was analyzed using RT-qPCR.

RESULTS: The SDL extracts showed no cytotoxic effects at any concentration, with cell viability exceeding 97% in all groups. Histological analysis revealed no epithelial disruption, inflammatory cell infiltration, or tissue damage in SDL-applied mucosa. Epithelial thickness exhibited a mild increase from day 1 to day 3 in both sham and SDL groups, with no significant intergroup differences. E-cadherin and pan-keratin expression patterns remained comparable between groups at all time points. RT-qPCR demonstrated a transient increase in inflammatory markers at day 1, which resolved by day 3 without sustained inflammation.

CONCLUSION: The newly formulated 3D-printable polyurethane-acrylate SDL demonstrated excellent biocompatibility and preserved oral mucosal integrity in vivo, supporting its potential clinical application as an alternative to conventional soft denture liners.

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты