MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1155/2021/6648535

Медицинская библиотека · Disease markers · 2021

Diagnostic Accuracy with Total Adenosine Deaminase as a Biomarker for Discriminating Pleural Transudates and Exudates in a Population-Based Cohort Study.

Maranhão Bernardo Henrique Ferraz, da Silva Junior Cyro Teixeira, Barillo Jorge Luiz, de Castro Carmem Lucia Teixeira, de Souza Joeber Bernardo Soares, Silva Patricia Siqueira, Stirbulov Roberto

Оценочное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

An initial step in the evaluation of patients with pleural effusion syndrome (PES) is to determine whether the pleural fluid is a transudate or an exudate.

OBJECTIVES

To investigate total adenosine deaminase (ADA) as a biomarker to classify pleural transudates and exudates.

METHODS

An assay of total ADA in pleural fluids (P-ADA) was observed using a commercial kit in a population-based cohort study.

RESULTS

157 pleural fluid samples were collected from untreated individuals with PES due to several causes. The cause most prevalent in transudate samples (21%, n = 33/157) was congestive heart failure (79%, 26/33) and that among exudate samples (71%, n = 124/157) was tuberculosis (28.0%, 44/124). There was no significant difference in the proportion of either sex between the transudate and exudate groups. The median values of P-ADA were significantly different (P < 0.0001) between both total exudates (18.4 U/L; IQR, 9.85-41.4) and exudates without pleural tuberculosis (11.0 U/L; IQR, 7.25-19.75) and transudates (6.85; IQR, 2.67-11.26). For exudates, the AUC was 0.820 (95% CI, 0.751-0.877; P < 0.001), with excellent discrimination. The optimum cut-off point in the ROC curve was determined as the level that provided the maximum positive likelihood ratio (PLR; 14.64; 95% CI, 2.11-101.9) and was22.0 U/L. For transudates, the AUC was 0.8245 (95% CI, 0.7470-0.9020; P < 0.0001). Internal validation of the AUC after 1000 resamples was evaluated with a tolerance minor than 2%. The clinical utility was equal to 92% (95% CI, 0.84 to 0.96, P < 0.05).

CONCLUSIONS

P-ADA is a useful biomarker for distinguishing pleural exudates from transudates.

Для цитирования: Maranhão Bernardo Henrique Ferraz, da Silva Junior Cyro Teixeira, Barillo Jorge Luiz, de Castro Carmem Lucia Teixeira, de Souza Joeber Bernardo Soares, Silva Patricia Siqueira, Stirbulov Roberto. Diagnostic Accuracy with Total Adenosine Deaminase as a Biomarker for Discriminating Pleural Transudates and Exudates in a Population-Based Cohort Study.. Disease markers. 2021. DOI: 10.1155/2021/6648535.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.