Asian journal of neurosurgery · 2020
Intraoperative Ultrasound an Economical Tool for Neurosurgeons: A Single-Center Experience.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Velho Vernon, Kharosekar Hrushikesh Umakant, Bhople Laxmikant, Domkundwar Shilpa
Аннотация
BACKGROUND: Over the past decade, the use of intraoperative image guidance in neurosurgery has gradually gained in importance. Apart from some sophisticated and very expensive techniques, intraoperative ultrasound (IOUS) is a simple and economical technique that allows the surgeon to localize deep-seated lesions under a real-time ultrasonic image display without dissection. The purpose of this study was to present our own preliminary experiences in various (n=1250) neurosurgical procedures carried out at our tertiary care centre in a developing country.
MATERIALS AND METHODS: A Prospective study was carried out in our department of neurosurgery at Grant Medical College and Sir J J Group of hospitals from January 2010 to May 2019. IOUS was used during various elective neurosurgical procedures done during this period as given in table no below. A total of 1250 patients, 850 supratentorial lesion, 290 infratentorial lesion and 110 spinal lesion, were included in this study. All studies were performed using an ultrasound machine with variable 3.5~7.5 MHz sector transducers. The echogenicity and pathomorphology between IOUS and computed tomography/magnetic resonance imaging (CT/MRI) of various disease entities were compared.
RESULTS: Intracranial structures could be well demonstrated by ultrasound once the skull was opened. Most of the intracranial lesions were hyperechoic, except those with a cystic component. IOUS was more sensitive in demonstrating non-enhanced solid lesions and lesions with a cystic component than was preoperative CT/MRI. The border between the tumor and healthy brain was better delineated on IOUS in all cases aiding in tumor resection.
CONCLUSIONS: High-resolution real-time IOUS is a convenient and user-friendly method for identifying, localizing, and characterizing the pathological focus during an operation. Such information is very important and can enhance surgical results.
MATERIALS AND METHODS: A Prospective study was carried out in our department of neurosurgery at Grant Medical College and Sir J J Group of hospitals from January 2010 to May 2019. IOUS was used during various elective neurosurgical procedures done during this period as given in table no below. A total of 1250 patients, 850 supratentorial lesion, 290 infratentorial lesion and 110 spinal lesion, were included in this study. All studies were performed using an ultrasound machine with variable 3.5~7.5 MHz sector transducers. The echogenicity and pathomorphology between IOUS and computed tomography/magnetic resonance imaging (CT/MRI) of various disease entities were compared.
RESULTS: Intracranial structures could be well demonstrated by ultrasound once the skull was opened. Most of the intracranial lesions were hyperechoic, except those with a cystic component. IOUS was more sensitive in demonstrating non-enhanced solid lesions and lesions with a cystic component than was preoperative CT/MRI. The border between the tumor and healthy brain was better delineated on IOUS in all cases aiding in tumor resection.
CONCLUSIONS: High-resolution real-time IOUS is a convenient and user-friendly method for identifying, localizing, and characterizing the pathological focus during an operation. Such information is very important and can enhance surgical results.