MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00330-007-0847-z

Медицинская библиотека · European radiology · 2008

Detection of colorectal hepatic metastases using MnDPDP MR imaging and diffusion-weighted imaging (DWI) alone and in combination.

Koh D M, Brown G, Riddell A M, Scurr E, Collins D J, Allen S D, Chau I, Cunningham D, deSouza N M, Leach M O, Husband J E

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

To compare the diagnostic accuracy of MnDPDP MR imaging and diffusion-weighted imaging (DWI), alone and in combination, for detecting colorectal liver metastases in patients with suspected metastatic disease. Thirty-three consecutive patients with suspected colorectal liver metastases underwent MR imaging. Three image sets (MnDPDP, DWI and combined MnDPDP and DWI) were reviewed independently by two observers. Lesions were scored on a five-point scale for malignancy and the areas (Az) under the receiver operating characteristic curves were calculated for each observer and image set. The sensitivity and specificity for lesion detection were calculated for each image set and compared. There were 83 metastases, 49 cysts and 1 haemangioma. Using the combined set resulted in the highest diagnostic accuracy for both observers (Az=0.94 and 0.96), with improved averaged sensitivity of lesion detection compared with the DWI set (p=0.01), and a trend towards improved sensitivity compared with the MnDPDP set (p=0.06). There was no difference in the averaged specificity using any of the three image sets (p>0.5). Combination of MnDPDP MR imaging and DWI resulted in the highest diagnostic accuracy and can increase sensitivity without loss in specificity.

Для цитирования: Koh D M, Brown G, Riddell A M, Scurr E, Collins D J, Allen S D, Chau I, Cunningham D, deSouza N M, Leach M O, Husband J E. Detection of colorectal hepatic metastases using MnDPDP MR imaging and diffusion-weighted imaging (DWI) alone and in combination.. European radiology. 2008. DOI: 10.1007/s00330-007-0847-z.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.