MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/j.1572-0241.2007.01731.x

Медицинская библиотека · The American journal of gastroenterology · 2008

Screening for esophagitis and Barrett's esophagus with wireless esophageal capsule endoscopy: a multicenter prospective trial in patients with reflux symptoms.

Galmiche Jean-Paul, Sacher-Huvelin Sylvie, Coron Emmanuel, Cholet Franck, Soussan Emmanuel Ben, Sébille Véronique, Filoche Bernard, d'Abrigeon Gilles, Antonietti Michel, Robaszkiewicz Michel, Le Rhun Marc, Ducrotté Philippe

СтатьяМногоцентровое исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND AND AIM: Esophageal capsule endoscopy (ECE) is a new technology that allows noninvasive investigation of the esophagus. Our aim was to evaluate prospectively the diagnostic yield of ECE in patients with chronic reflux symptoms.

PATIENTS AND

METHODS

Eighty-nine patients (40 men, mean age 54 yr) referred to five endoscopic centers for esophagogastroduodenoscopy (EGD) were enrolled. Patients first underwent ECE, then EGD; endoscopists who performed the EGD were blind to the ECE data that were interpreted separately by two independent readers. The Los Angeles, Prague, and Montreal classification systems were used to describe endoscopic findings.

RESULTS

Seventy-seven patients completed the study. Esophagitis and endoscopically suspected esophageal metaplasia (ESEM) were present in 24 and 10 patients, respectively. Columnar lining was histologically confirmed in seven patients (3 with specialized intestinal metaplasia and 4 with gastric metaplasia). The kappa values for interobserver agreement regarding the diagnosis of esophagitis and ESEM were 0.67 (0.49-0.85) and 0.49 (0.17-0.81), respectively. The diagnostic yields of ECE to detect esophagitis and ESEM were as follows: sensitivity 79% and 60%, specificity 94% and 100%, positive predictive value (PPV) 83% and 100%, negative predictive value (NPV) 92% and 95%, respectively.

CONCLUSION

As a screening tool in patients with reflux symptoms, ECE has an excellent specificity and NPV for the diagnosis of esophagitis and ESEM. However, its sensitivity for the diagnosis of ESEM is not optimal. Further studies are necessary to improve the procedure, and to compare the cost-effectiveness of strategies using ECE or EGD.

Для цитирования: Galmiche Jean-Paul, Sacher-Huvelin Sylvie, Coron Emmanuel, Cholet Franck, Soussan Emmanuel Ben, Sébille Véronique, Filoche Bernard, d'Abrigeon Gilles, Antonietti Michel, Robaszkiewicz Michel, Le Rhun Marc, Ducrotté Philippe. Screening for esophagitis and Barrett's esophagus with wireless esophageal capsule endoscopy: a multicenter prospective trial in patients with reflux symptoms.. The American journal of gastroenterology. 2008. DOI: 10.1111/j.1572-0241.2007.01731.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.