CS-VIBE accelerates cranial nerve MR imaging for the diagnosis of facial neuritis: comparison of the diagnostic performance of post-contrast MPRAGE and CS-VIBE.

Chung Mi Sun, Yim Younghee, Sung Jae Kon, Kim InSeong, Nickel Dominik, Chang Munyoung, Mun Seog-Kyun, Byun Jun Soo

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

We aimed to compare the diagnostic performance of post-contrast 3D compressed sensing volume-interpolated breath-hold examination (CS-VIBE) and 3D T1 magnetization-prepared rapid-acquisition gradient-echo (MPRAGE) in detecting facial neuritis.

MATERIALS AND

METHODS

Between February 2019 and September 2019, 60 patients (30 facial palsy patients and 30 controls) who underwent contrast-enhanced cranial nerve MRI with both conventional MPRAGE and CS-VIBE (scan time: 6 min 8 s vs. 2 min 48 s) were included in this retrospective study. All images were independently reviewed by three radiologists for the presence of facial neuritis. In patients with facial palsy, signal-to-noise ratio (SNR) of the pons, enhancement degree and contrast-to-noise ratio (CNRnerve-CSF) of the facial nerve were measured. The overall image quality, artifacts, and facial nerve discrimination were analyzed. The sensitivity and specificity of both sequences were calculated with the clinical diagnosis as a reference.

RESULTS

CS-VIBE had comparable performance in the detection of facial neuritis to that of MPRAGE (sensitivity and specificity, 97.8% and 99.4% vs. 100.0% and 99.4% in pooled analysis; 97.8% and 98.9% vs. 100.0% and 98.9% in patents with facial palsy, p value > 0.05 for all). CS-VIBE showed significantly lower SNR (p value < 0.001 for all), but significantly higher CNRnerve-CSF (p value < 0.05 for all) than MPRAGE. CS-VIBE also performed better in the overall image quality, artifacts, and facial nerve discrimination than MPRAGE (p value < 0.001 for all).

CONCLUSION

CS-VIBE achieved comparable diagnostic performance for facial neuritis compared to the conventional MPRAGE, with the scan time being half of that of MPRAGE.

KEY POINTS: • Post-contrast 3D CS-VIBE MRI is a reliable method for the diagnosis of facial neuritis. • CS-VIBE reduces the scan time of cranial nerve MRI by more than half compared to conventional T1-weighted image. • CS-VIBE had better performance in contrast-to-noise ratio and favorable image quality compared with conventional T1-weighted image.

Для цитирования: Chung Mi Sun, Yim Younghee, Sung Jae Kon, Kim InSeong, Nickel Dominik, Chang Munyoung, Mun Seog-Kyun, Byun Jun Soo. CS-VIBE accelerates cranial nerve MR imaging for the diagnosis of facial neuritis: comparison of the diagnostic performance of post-contrast MPRAGE and CS-VIBE.. European radiology. 2021. DOI: 10.1007/s00330-021-08102-6.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.