MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2214/ajr.11.8275

Медицинская библиотека · AJR. American journal of roentgenology · 2012

Adaptive iterative dose reduction using 3D processing for reduced- and low-dose pulmonary CT: comparison with standard-dose CT for image noise reduction and radiological findings.

Ohno Yoshiharu, Takenaka Daisuke, Kanda Tomonori, Yoshikawa Takeshi, Matsumoto Sumiaki, Sugihara Naoki, Sugimura Kazuro

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVE

The purpose of this study was to determine the utility of adaptive iterative dose reduction using 3D processing (AIDR 3D) for image noise reduction and assessment of radiologic findings obtained with reduced- and low-dose chest CT in patients with various pulmonary diseases.

SUBJECTS AND

METHODS

Chest CT examinations at three different tube current settings and using 16- and 64-MDCT scanners were performed for 37 patients. Standard-dose (150 mAs) data were reconstructed as thin-section CT without AIDR 3D, and low-dose (25 mAs) and reduced-dose (50 mAs) data were reconstructed as thin-section CT without and with AIDR 3D. To compare image quality, image noises at all CT doses were quantitatively assessed by region of interest measurements. For comparison of radiologic finding assessments, likelihoods of occurrence of emphysema, ground-glass opacity, reticular opacity, bronchiectasis, honeycomb pattern, and nodules were evaluated on a 5-point scale. Then, image noise and agreements of radiologic findings between standard-dose CT and others were statistically evaluated.

RESULTS

The image quality scores of reduced- and low-dose CT without AIDR 3D were significantly lower than those of both protocols with AIDR 3D and standard-dose CT (p<0.05). All intermethod agreements for emphysema, ground-glass opacity, bronchiectasis, honeycomb pattern, and nodules, except for those observed on low-dose CT without AIDR 3D, were almost perfect (κ>0.81).

CONCLUSION

AIDR 3D is useful for image noise reduction and assessment of radiologic findings obtained with reduced- and low-dose CT for patients with various pulmonary diseases.

Для цитирования: Ohno Yoshiharu, Takenaka Daisuke, Kanda Tomonori, Yoshikawa Takeshi, Matsumoto Sumiaki, Sugihara Naoki, Sugimura Kazuro. Adaptive iterative dose reduction using 3D processing for reduced- and low-dose pulmonary CT: comparison with standard-dose CT for image noise reduction and radiological findings.. AJR. American journal of roentgenology. 2012. DOI: 10.2214/ajr.11.8275.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.