m+Medelevator.RU
← Поиск публикаций
JACC. Cardiovascular interventions · 2025

Long-Term Outcomes of BAV-0 Patients Compared With BAV-1 and TAV Patients After TAVR.

СтатьяСравнительное исследованиеМногоцентровое исследованиеПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Li Weiya, Jia Yuheng, Li Hongde, Kobari Yusuke, Li Junli, Feng Yuan, Peng Yong, Wei Jiafu, Zhao Zhengang, Xiong Tianyuan, Yang Haoran, Song Chengxiang, Lei Wenhua, Peng Shiqin, Yin Yue, Qiao Xuechen, Wang Duolao, Kim Won-Keun, De Backer Ole, Chen Mao

Аннотация

BACKGROUND: Differences in long-term clinical outcomes following transcatheter aortic valve replacement (TAVR) in different anatomical subtypes of aortic valve stenosis (AS), specifically tricuspid aortic valves (TAV) and bicuspid aortic valves (BAV) of types 0 (BAV-0) and 1 (BAV-1), are not well understood.

OBJECTIVES: The authors sought to report and compare the long-term clinical outcomes among patients with different anatomical subtypes of AS undergoing TAVR.

METHODS: We conducted an international retrospective cohort study involving patients who underwent TAVR for severe AS at 3 large, high-volume heart centers in China, Germany, and Denmark before October 2018. Five-year follow-up ended on October 30, 2023, and the primary endpoint was all-cause mortality.

RESULTS: A total of 2,553 AS patients (BAV-0: n = 134; BAV-1: n = 305; TAV: n = 2,114) who underwent TAVR more than 5 years ago were included. The mean age of this cohort was 79.9 ± 6.8 years, and the median Society of Thoracic Surgeons score was 3.6% [Q1-Q3: 2.4%-5.4%]. The median follow-up time was 3.24 years (Q1-Q3: 1.25-5.00 years). At 5 years, BAV-1 (adjusted HR: 2.38 [95% CI: 1.32-4.28]; P = 0.004) and TAV (adjusted HR: 3.02 [95% CI: 1.71-5.31]; P < 0.001) had a higher risk for all-cause mortality after TAVR compared with BAV-0. BAV patients who were treated with balloon-expandable valves had a higher long-term all-cause mortality (41.7% [28.5%-52.5%] vs 23.6% [17.9%-28.8%]; HR: 1.63 [95% CI: 1.05-2.51]; P = 0.028) compared with those with self-expanding valves.

CONCLUSIONS: Among patients with severe AS undergoing TAVR, BAV-0 was associated with a better long-term prognosis compared with TAV and BAV-1.

Предметные рубрики MeSH