PURPOSE: To evaluate the ability of OCT optic nerve head (ONH) and macular parameters to detect disease progression in eyes with advanced structural glaucomatous damage of the circumpapillary retinal nerve fiber layer (cRNFL).

DESIGN

Longitudinal study.

PARTICIPANTS

Forty-four eyes from 37 patients with advanced average cRNFL damage (≤60 μm) followed up for an average of 4.0 years.

METHODS

All patients were examined with spectral-domain OCT and visual field (VF) assessment during at least 4 visits.

MAIN OUTCOME MEASUREMENTS: Visual field mean deviation (MD) and VF index. OCT cRNFL (average, superior, and inferior quadrants), ganglion cell-inner plexiform layer (GCIPL) (average, superior, and inferior), rim area, cup volume, average cup-to-disc (C:D) ratio, and vertical C:D ratio.

RESULTS

At baseline, patients had a median VF MD of -10.18 dB and mean cRNFL of 54.55±3.42 μm. The rate of change for MD and VF index were significant. No significant rate of change was noted for cRNFL, whereas significant (P < 0.001) rates were detected for GCIPL (-0.57±0.05 μm/year) and ONH parameters such as rim area (-0.010±0.001 mm2/year).

CONCLUSIONS

Macula GCIPL and ONH parameters may be useful in tracking progression in patients with advanced glaucoma.

Для цитирования: Lavinsky Fabio, Wu Mengfei, Schuman Joel S, Lucy Katie A, Liu Mengling, Song Youngseok, Fallon Julia, de Los Angeles Ramos Cadena Maria, Ishikawa Hiroshi, Wollstein Gadi. Can Macula and Optic Nerve Head Parameters Detect Glaucoma Progression in Eyes with Advanced Circumpapillary Retinal Nerve Fiber Layer Damage?. Ophthalmology. 2018. DOI: 10.1016/j.ophtha.2018.05.020.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.