MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1371/journal.pone.0198830

Медицинская библиотека · PloS one · 2018

Investigation of lateral geniculate nucleus volume and diffusion tensor imaging in patients with normal tension glaucoma using 7 tesla magnetic resonance imaging.

Schmidt Manuel A, Knott Michael, Heidemann Robin, Michelson Georg, Kober Tobias, Dörfler Arnd, Engelhorn Tobias

Клиническое исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

There is evidence that glaucoma is a neurodegenerative disease involving the whole visual pathway. We prospectively examined potential benefits of volumetry of the lateral geniculate nucleus (LGN) and diffusion tensor imaging (DTI) using a new 7T scanner.

METHODS

20 patients with normal tension glaucoma and 16 control individuals were examined. LGN volume and fractional anisotropy (FA) of the optic tract (OT) and the optic radiation (OR) and their correlation with RNFL (retinal nerve fiber layer) thickness were analyzed.

RESULTS

LGN volume was significantly reduced in NTG (60.9 vs 88.3; p < 0.05). FA of the OT (right: 0.35 vs 0.66, left: 0.36 vs 0.67; p < 0.05) and of the OR (right: 0.41 vs 0.70, left: 0.41 vs 0.69; p < 0.05) was also significantly reduced. Nasal RNFL thickness correlated with the volume of the contralateral LGN (r = 0.471, p = 0.05). Temporal RNFL thickness correlated with the volume of the ipsilateral LGN (r = 0.603, p = 0.015).

CONCLUSION

NTG leads to significant atrophy of the LGN compared to controls. FA of the optic tract and the optic radiation is reduced in NTG as sign of axonal degeneration. RNFL thickness but not FA correlates with LGN volume.

Для цитирования: Schmidt Manuel A, Knott Michael, Heidemann Robin, Michelson Georg, Kober Tobias, Dörfler Arnd, Engelhorn Tobias. Investigation of lateral geniculate nucleus volume and diffusion tensor imaging in patients with normal tension glaucoma using 7 tesla magnetic resonance imaging.. PloS one. 2018. DOI: 10.1371/journal.pone.0198830.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.