Dhingra Lovedeep S, Croon Philip M, Batinica Bruno, Aminorroaya Arya, Pedroso Aline F, Oikonomou Evangelos K, Khera Rohan
Аннотация
BACKGROUND: The scientific literature on artificial intelligence-enabled electrocardiography (AI-ECG) has defined a robust performance of AI models in detecting and predicting several structural heart disorders (SHDs) using ECGs. However, as a diagnostic test, the real-world utility of AI-ECG reliability requires the consistency of its results when repeated under similar conditions.
AIM: To evaluate the reliability of AI-ECG models for different ECGs for the same person, across different diagnostic labels, and using varied modeling approaches.
METHODS: We used ECG images (2000-2024) from 5 hospitals and an outpatient network within a large, integrated US health system. For each individual, we identified multiple ECGs recorded within a 30-day period. We evaluated 7 models: 6 convolutional neural networks (CNNs) trained to detect individual SHDs, including LV systolic dysfunction, left valve diseases and severe LVH; an ensemble XGBoost integrating individual CNNs as a composite screen for multiple SHDs. We used concordance correlation coefficient (CCC), Spearman correlation, Cohen's kappa, and percent agreement in binary screen status to test model reliability. We evaluated factors associated with different AI-ECG outputs (Δ probability> 0.5) and assessed stability across ECG layouts (digital, printed, photo).
RESULTS: Across sites, we identified 1,118,263 ECG pairs, with a median 1 (1-3) days between ECGs. The ensemble XGBoost had the higher test-retest correlation (CCC: 0.89-0.92) and agreement (kappa: 0.75-0.82) between pairs compared with CNNs (CCC: 0.78-0.88; kappa: 0.57-0.72). After adjusting for demographics, ECG pairs that included one or both inpatient ECG were significantly more likely to yield unstable predictions (ORs: 1.60 [1.50-1.70] and 1.91 [1.78-2.05], respectively) compared with pairs with both ECGs obtained in outpatient settings. Among outpatient pairs across sites, the XGBoost model had a CCC of 0.89-0.94, a Spearman correlation of 0.90-0.94, and a kappa of 0.78-0.84, with concordance rates of 89-92%. Notably, ensemble model predictions were also stable across different ECG layouts.
CONCLUSION: An ensemble AI-ECG model integrating multiple CNN predictions had higher reliability compared with models for individual disorders. Discordance was more common in inpatient ECGs, suggesting instability in high-acuity settings. Reliable ensemble AI-ECG model outputs support readiness for clinical implementation for SHD screening.
AIM: To evaluate the reliability of AI-ECG models for different ECGs for the same person, across different diagnostic labels, and using varied modeling approaches.
METHODS: We used ECG images (2000-2024) from 5 hospitals and an outpatient network within a large, integrated US health system. For each individual, we identified multiple ECGs recorded within a 30-day period. We evaluated 7 models: 6 convolutional neural networks (CNNs) trained to detect individual SHDs, including LV systolic dysfunction, left valve diseases and severe LVH; an ensemble XGBoost integrating individual CNNs as a composite screen for multiple SHDs. We used concordance correlation coefficient (CCC), Spearman correlation, Cohen's kappa, and percent agreement in binary screen status to test model reliability. We evaluated factors associated with different AI-ECG outputs (Δ probability> 0.5) and assessed stability across ECG layouts (digital, printed, photo).
RESULTS: Across sites, we identified 1,118,263 ECG pairs, with a median 1 (1-3) days between ECGs. The ensemble XGBoost had the higher test-retest correlation (CCC: 0.89-0.92) and agreement (kappa: 0.75-0.82) between pairs compared with CNNs (CCC: 0.78-0.88; kappa: 0.57-0.72). After adjusting for demographics, ECG pairs that included one or both inpatient ECG were significantly more likely to yield unstable predictions (ORs: 1.60 [1.50-1.70] and 1.91 [1.78-2.05], respectively) compared with pairs with both ECGs obtained in outpatient settings. Among outpatient pairs across sites, the XGBoost model had a CCC of 0.89-0.94, a Spearman correlation of 0.90-0.94, and a kappa of 0.78-0.84, with concordance rates of 89-92%. Notably, ensemble model predictions were also stable across different ECG layouts.
CONCLUSION: An ensemble AI-ECG model integrating multiple CNN predictions had higher reliability compared with models for individual disorders. Discordance was more common in inpatient ECGs, suggesting instability in high-acuity settings. Reliable ensemble AI-ECG model outputs support readiness for clinical implementation for SHD screening.