DOI 10.1016/j.hrthm.2021.03.042

Медицинская библиотека · Heart rhythm · 2021

Left-axis deviation in patients with nonischemic heart failure and left bundle branch block is a purely electrical phenomenon.

Abu-Alrub Saer, Strik Marc, Huntjens Peter, Ramirez F Daniel, Potse Mark, Cochet Hubert, Marchand Hugo, Buliard Samuel, Eschalier Romain, Haïssaguerre Michel, Bordachar Pierre, Ploux Sylvain

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Possible mechanisms of left-axis deviation (LAD) in the setting of left bundle branch block (LBBB) include differences in cardiac electrophysiology, structure, or anatomic axis.

OBJECTIVE

The purpose of this study was to clarify the mechanism(s) responsible for LAD in patients with LBBB.

METHODS

Twenty-nine patients with nonischemic cardiomyopathies and LBBB underwent noninvasive electrocardiographic imaging (ECGi), cardiac computed tomography, and magnetic resonance imaging in order to define ventricular electrical activation, characterize cardiac structure, and determine the cardiac anatomic axis.

RESULTS

Sixteen patients had a normal QRS axis (NA) (mean axis 8° ± 23°), whereas 13 patients had LAD (mean axis -48° ± 13°; P <.001). Total activation times were longer in the LAD group (112 ± 25 ms vs 91 ± 14 ms; P = .01) due to delayed activation of the basal anterolateral region (107 ± 10 ms vs 81 ± 17 ms; P <.001). Left ventricular (LV) activation in patients with LAD was from apex to base, in contrast to a circumferential pattern of activation in patients with NA. Apex-to-base delay was longer in the LA group (95 ± 13 ms vs 64 ± 21 ms; P <.001) and correlated with QRS frontal axis (R2 = 0.67; P <.001). Both groups were comparable with regard to LV end-diastolic volume (295 ± 84 mL vs LAD 310 ± 91 mL; P = .69), LV mass (177 ± 33 g vs LAD 180 ± 37 g; P = .83), and anatomic axis.

CONCLUSION

LAD in LBBB appears to be due to electrophysiological abnormalities rather than structural factors or cardiac anatomic axis.

Для цитирования: Abu-Alrub Saer, Strik Marc, Huntjens Peter, Ramirez F Daniel, Potse Mark, Cochet Hubert, Marchand Hugo, Buliard Samuel, Eschalier Romain, Haïssaguerre Michel, Bordachar Pierre, Ploux Sylvain. Left-axis deviation in patients with nonischemic heart failure and left bundle branch block is a purely electrical phenomenon.. Heart rhythm. 2021. DOI: 10.1016/j.hrthm.2021.03.042.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.