MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ijcard.2021.02.028

Медицинская библиотека · International journal of cardiology · 2021

Transcatheter aortic valve replacement performed with selective telemetry monitoring: A prospective study.

Akodad Mariama, Aldhaheri Eissa, Marin Gregory, Roubille François, Macia Jean-Christophe, Gandet Thomas, Delseny Delphine, Schmutz Laurent, Lattuca Benoit, Robert Pierre, Dubard Arnaud, Robert Gabriel, Targosz Frederic, Maupas Eric, Albat Bernard, Cayla Guillaume, Leclercq Florence

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Telemetry monitoring (TM) with or without intensive care unit (ICU) admission is the standard of care after Transcatheter aortic valve replacement (TAVR). Regarding to improvements of the technique and procedural results, TM may be considered only in selected patients. We aimed to confirm feasibility and safety of selective TM in patients undergoing TAVR.

METHODS

We prospectively evaluated 449 consecutive patients undergoing TAVR. Patients were transferred to general cardiology ward (GCW) without TM after the procedure when stable clinical state, transfemoral access, no baseline right bundle branch block (RBBB), left ventricular ejection fraction (LVEF) > 40%, and no complication including any electrocardiogram (ECG) change within 1 h after the procedure ("low-risk" group). Others patients were considered for TM in ICU ("high-risk" group). The primary endpoint evaluated in-hospital major adverse events after unit admission according to VARC-2 criteria.

RESULTS

The mean age was 81.8 ± 7.5 years and mean EuroSCORE II was 7.5 ± 4.8%. In total, 116 patients (25.8%) were considered as "low-risk" patients and 163 patients (36.3%) were referred to GCW, including those with immediate pacemaker implantation. A total of 96 patients (21.3%) reached the primary endpoint including mainly conductive disorders (12.8%). No major adverse events, particularly no late severe conductive disorder, occurred in the "low-risk" group (negative predictive value of 100%). Baseline RBBB (p < 0.01), LVEF < 40% (p = 0.02) and "high-risk" group (p < 0.01) were predictive of outcomes.

CONCLUSIONS

Using rigorous periprocedural selection criteria, patients' admission in GCW without TM can be routinely and safely performed in 1/3 of patients after TAVR.

Для цитирования: Akodad Mariama, Aldhaheri Eissa, Marin Gregory, Roubille François, Macia Jean-Christophe, Gandet Thomas, Delseny Delphine, Schmutz Laurent, Lattuca Benoit, Robert Pierre, Dubard Arnaud, Robert Gabriel, Targosz Frederic, Maupas Eric, Albat Bernard, Cayla Guillaume, Leclercq Florence. Transcatheter aortic valve replacement performed with selective telemetry monitoring: A prospective study.. International journal of cardiology. 2021. DOI: 10.1016/j.ijcard.2021.02.028.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.