MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/ehf2.13181

Медицинская библиотека · ESC heart failure · 2021

Impact of QRS morphology on response to conduction system pacing after atrioventricular junction ablation.

Wu Shengjie, Cai Mengxing, Zheng Rujie, Wang Songjie, Jiang Limeng, Xu Lei, Shi Ruiyu, Xiao Fangyi, Ellenbogen Kenneth A, Cha Yongmei, Su Lan, Huang Weijian

СтатьяНаблюдательное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

AIMS: His-Purkinje conduction system pacing (HPCSP) utilizing His (HBP) or left bundle branch pacing (LBBP) in patients with atrial fibrillation (AF) and wide QRS duration has not been well studied. We assessed the benefit of left bundle branch block (LBBB) correction during HPCSP in AF patients undergoing atrioventricular junction (AVJ) ablation with LBBB, compared with those with narrow QRS duration.

METHODS AND

RESULTS

This is an observational study in consecutive patients with typical LBBB or narrow QRS duration in whom we attempted HPCSP after AVJ ablation for refractory AF with a left ventricular ejection fraction (LVEF) ≤ 50%. Echocardiographic responses and clinical outcomes were assessed at baseline and during 1 year of follow-up. A total of 178 patients were enrolled, of which 170 achieved AVJ ablation + permanent HPCSP (age 69.3 ± 10.1 years; LVEF 34.3 ± 7.7%), 133 (78.2%) patients had a narrow QRS duration, and 37 (21.2%) had an LBBB. The QRS duration changed from a baseline of 159.7 ± 16.6 ms to a paced QRS duration of 110.4 ± 12.7 ms in the LBBB cohort and from 95.6 ± 10.4 to 100.8 ± 14.5 ms (both P < 0.001) in the narrow QRS cohort after AVJ ablation and pacing. Compared with the narrow QRS cohort, the LBBB cohort showed a greater absolute increase in LVEF (+22.3% vs. +14.2%, P < 0.001), higher super responder rate (71.4% vs. 49.2%, P = 0.011), and greater New York Heart Association (NYHA) class improvement (-1.9 vs. -1.4, P < 0.001) at 1 year.

CONCLUSION

Patients with LBBB have greater improvement in LVEF and NYHA class function than patients with narrow QRS from HPCSP after AVJ ablation.

Для цитирования: Wu Shengjie, Cai Mengxing, Zheng Rujie, Wang Songjie, Jiang Limeng, Xu Lei, Shi Ruiyu, Xiao Fangyi, Ellenbogen Kenneth A, Cha Yongmei, Su Lan, Huang Weijian. Impact of QRS morphology on response to conduction system pacing after atrioventricular junction ablation.. ESC heart failure. 2021. DOI: 10.1002/ehf2.13181.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.