The impact of a modified electronic probe tip design on patient perception of discomfort during periodontal probing using standardized probing force: A randomized controlled trial.
Аннотация
AIMS: This study evaluated pain associated with electronic probing comparing two commercially available probe tip designs using standardized force.
MATERIAL AND
METHODS
Twenty adult patients with slight-moderate chronic periodontitis received periodontal probing using controlled-force electronic probe at 2 visits. In visit 1, a random arch was probed with either a ball-end (0.6 mm diameter, 408 kPa; Test) or straight (0.45 mm diameter, 726 kPa; Control) probe tip. The opposing arch was then probed using the other probe tip. Discomfort associated with each probing episode was recorded using visual analogue scale (VAS). 7 days later, tip assignments were alternated from visit 1 and VAS re-scored. VAS scores were compared by probe tip, arches and visits.
RESULTS
Both tips provided similar VAS scores (median 13.5 for ball-end and 14 for straight, p = .3713). However, the straight tip was associated with decreased VAS scores in the maxilla (p = .01). Overall, VAS values did not differ by arch or study visit. Individual VAS scores showed high levels of correlation between study visits and between tips used (R2 = .86 and 0.64, respectively, p < .0001).
CONCLUSIONS
Both probing approaches were associated with low levels of pain on probing. The straight tip may be perceived as more comfortable in the maxilla.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.