Cao Yukun, Gu Chunhu, Sun Guocheng, Yu Shiqiang, Wang Hongbing, Yi Dinghua

Аннотация

BACKGROUND: We performed the first quadruple valve replacement with mechanical valves, combined with the correction of complex congenital heart disease on November 17, 1999. We report here the 11-year follow-up study.

METHODS: A 47-year-old man with subacute rheumatic endocarditis, a ventricular septal defect, and an obstruction of the right ventricular outflow tract required replacement of the aortic, mitral, tricuspid, and pulmonary valves; repair of the ventricular septal defect; and relief of the obstruction of the right ventricular outflow tract. The surgery was done on November 17, 1999, after careful systemic preparation of the patient. Warfarin therapy with a target international normalized ratio (INR) range of 1.5 to 2.0 was used. Follow-up included monitoring the INR, recording the incidences of thromboembolic and bleeding events, electrocardiography, radiography, and echocardiography evaluations.

RESULTS: The patient's INR was maintained between 1.5 and 2.0. All 4 mechanical prosthetic heart valves worked well. He is in generally good health without any thromboembolic or bleeding complications.

CONCLUSIONS: Long-term management is challenging for patients who have experienced quadruple valve replacement with mechanical valves; however, promising results could mean that replacement of all 4 heart valves in 1 operation is feasible in patients with quadruple valve disease, and an INR of 1.5 to 2.0 could be appropriate for Chinese patients with undergoing valve replacement with mechanical valves.