MedElevator Войти в исследования
← Поиск публикаций

DOI 10.5603/cj.a2018.0111

Медицинская библиотека · Cardiology journal · 2018

Coronary plaque redistribution after stent implantation is determined by lipid composition: A NIRS-IVUS analysis.

Roleder Tomasz, Dobrolinska Magdalena, Pociask Elzbieta, Wanha Wojciech, Smolka Grzegorz, Walkowicz Wojciech, Parma Radoslaw, Lebek Mariusz, Bochenek Tomasz, Pietraszewski Przemysław, Kedhi Elvin, Ochala Andrzej, Gasior Zbigniew, Ali Ziad A, Wojakowski Wojciech

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

The composition of plaque impacts the results of stenting. The following study evaluated plaque redistribution related to stent implantation using combined near-infrared spectroscopy and intravascular ultrasound (NIRS-IVUS) imaging.

METHODS

The present study included 49 patients (mean age 66 ± 11 years, 75% males) presenting with non-ST elevation myocardial infarction (8%), unstable angina (49%) and stable coronary artery disease (43%). The following parameters were analyzed: mean plaque volume (MPV, mm3), plaque burden (PB, %), remodeling index (RI), and maximal lipid core burden index in a 4 mm segment (maxLCBI4mm). High-lipid burden lesions (HLB) were defined as by maxLCBI4mm > 265 with positive RI. Otherwise plaques were defined as low-lipid burden lesions (LLB). Measurements were done in the target lesion and in 4 mm edges of the stent before and after stent implantation.

RESULTS

MPV and maxLCBI4mm decreased in both HLB (MPV 144.70 [80.47, 274.25] vs. 97.60 [56.82, 223.45]; maxLCBI4mm: 564.11 ± 166.82 vs. 258.11 ± 234.24, p = 0.004) and LLB (MPV: 124.50 [68.00, 186.20] vs. 101.10 [67.87, 165.95]; maxLCBI4mm: 339.07 ± 268.22 vs. 124.60 ± 160.96, p < 0.001), but MPV decrease was greater in HLB (28.00 [22.60, 57.10] vs. 13.50 [1.50, 28.84], p = 0.019). Only at the proximal stent edge of LLB, maxLCBI4mm decreased (34 [0, 207] vs. 0 [0, 45], p = 0.049) and plaque burden increased (45.48 [40.34, 51.55] vs. 51.75 [47.48, 55.76], p = 0.030).

CONCLUSIONS

NIRS-IVUS defined HLB characterized more significant decreases in plaque volume by stenting. Plaque redistribution to the proximal edge of the implanted stent occurred only in LLB.

Для цитирования: Roleder Tomasz, Dobrolinska Magdalena, Pociask Elzbieta, Wanha Wojciech, Smolka Grzegorz, Walkowicz Wojciech, Parma Radoslaw, Lebek Mariusz, Bochenek Tomasz, Pietraszewski Przemysław, Kedhi Elvin, Ochala Andrzej, Gasior Zbigniew, Ali Ziad A, Wojakowski Wojciech. Coronary plaque redistribution after stent implantation is determined by lipid composition: A NIRS-IVUS analysis.. Cardiology journal. 2018. DOI: 10.5603/cj.a2018.0111.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.