The prognostic value of the relationship between right atrial and pulmonary capillary wedge pressure in diverse cardiovascular conditions.
Аннотация
BACKGROUND
Physical examination of jugular venous pressure is used to estimate right atrial (RA) pressure and infer left-sided filling pressure to assist volume management. Previous studies in advanced heart failure patients showed about 75% concordance between RA and pulmonary capillary wedge (PCW) pressures. We sought to determine the relationship between mean RA and mean PCW pressure and assess the clinical significance in a broad population of patients undergoing invasive right heart catheterization (RHC).
METHODS
We examined 4135 RHC cases at a single academic medical center from February 2007 to December 2014, analyzing baseline variables, hemodynamic data, and in-hospital mortality.
RESULTS
The overall Pearson correlation for mean RA and PCW pressures was 0.68 with 70% concordance between dichotomized pressures (RA ≥10 and PCW ≥22 mmHg). Results were similar in subgroups with heart failure (r=0.67, 72%), STEMI/NSTEMI (r=0.60, 69%), unstable angina (r=0.78, 69%), stable/no angina (r=0.72, 67%), and valvular disease (r=0.61, 72%; Chi-square P=.15). Mean RA pressure was independently associated with in-hospital mortality in multivariate analysis (OR 1.12 [95% CI 1.081-1.157] per 1 mmHg increase, P<.001). The RA/PCW ratio was not independently associated with in-hospital mortality. Mean RA pressure was also weakly associated with worse renal function (rho=-0.16, P<.001).
CONCLUSION
In patients undergoing right catheterization for diverse indications, the mean RA and PCW pressures correlated moderately well, but there was discordance in a sizable minority, in whom assessment of left-sided filling pressures using estimated jugular venous pressure may be misleading. Elevated right atrial pressure is a marker for in-hospital mortality.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.