MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1136/bjophthalmol-2012-301662

Медицинская библиотека · The British journal of ophthalmology · 2012

Penetrating keratoplasty using femtosecond laser-enabled keratoplasty with zig-zag incisions versus a mechanical trephine in patients with keratoconus.

Gaster Ronald N, Dumitrascu Oanna, Rabinowitz Yaron S

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND/AIMS: This paper will compare the visual outcomes of two different penetrating keratoplasty (PKP) techniques in patients with keratoconus. It is a retrospective comparative surgical case series of 116 keratoconus patients (137 eyes) who had PKP at the Cornea Eye Institute, Beverly Hills, California, USA.

METHODS

56 keratoconus patients (66 eyes) underwent femtosecond laser-enabled keratoplasty (FLEK) with a zig-zag incision configuration. Their visual parameters were compared with those of 60 patients (71 eyes) who had traditional blade mechanical trephination PKP. The range of follow-up was between 3 and 6 months. The main outcome measures included uncorrected visual acuity and best spectacle-corrected visual acuity (BSCVA), manifest refractive spherical equivalent and topographically determined astigmatism.

RESULTS

BSCVA was significantly better as early as 3 months postoperatively (p=0.001) in the FLEK group. Visual recovery to 20/40 after 3 months was significantly better in the FLEK group (p<0.001). Topographic astigmatism was lower in the FLEK group, but the difference between the two groups reached significance only at 3 months of follow-up (p=0.001). Postoperative complications noted were not different between the two groups.

CONCLUSIONS

Faster visual recovery and better long-term outcomes were observed in keratoconus patients who had FLEK compared with those who had the mechanical PKP procedure with 6 months of postoperative follow-up.

Для цитирования: Gaster Ronald N, Dumitrascu Oanna, Rabinowitz Yaron S. Penetrating keratoplasty using femtosecond laser-enabled keratoplasty with zig-zag incisions versus a mechanical trephine in patients with keratoconus.. The British journal of ophthalmology. 2012. DOI: 10.1136/bjophthalmol-2012-301662.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.