DOI 10.1016/j.jcrs.2012.02.039
Comparison of 2 types of intrastromal corneal ring segments for keratoconus.
Аннотация
PURPOSE: To assess the effectiveness and safety of 2 types of 6.0 mm intrastromal corneal ring segments (ICRS) in patients with mild to severe keratoconus.
SETTING
Lebanese American University, Beirut, Lebanon.
DESIGN
Retrospective comparative case series.
METHODS
Eyes had implantation of Intacs SK ICRS (Group 1) or Keraring SI6 ICRS (Group 2). Visual acuity (logMAR), refraction, keratometry, and higher-order aberrations were compared 6 months and 1 year postoperatively.
RESULTS
Group 1 comprised 66 eyes and Group 2, 107 eyes. The groups were comparable preoperatively. One-year postoperatively, the mean uncorrected distance visual acuity improved by 0.62 logMAR ± 0.19 (SD) in Group 1 and by 0.67 ± 0.17 logMAR in Group 2 (P=.211). The mean corrected distance visual acuity improved by 0.12 ± 0.11 logMAR and by 0.08 ± 0.13, respectively (P=.301). The spherical equivalent decreased by a mean of 2.80 ± 2.87 D and 2.65 ± 3.00 D, respectively (P=.572). Keratometry (K) flat and K steep decreased by a mean of 1.51 ± 1.57 D and 2.24 ± 1.61 D, respectively, in Group 1 and by 1.10 ± 2.00 D and 1.44 ± 1.64 D, respectively, in Group 2 (P=.667 and P=.184, respectively). Primary coma root mean square decreased by a mean of 1.09 ± 0.66 μm in Group 1 and 0.99 ± 0.72 μm in Group 2 (P=.716).
CONCLUSION
Both ICRS models significantly improved visual function in patients with keratoconus, with comparable postoperative profiles and no major complications.
FINANCIAL DISCLOSURE: No author has a financial or proprietary interest in any material or method mentioned.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.