MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.cca.2018.01.034

Медицинская библиотека · Clinica chimica acta; international journal of clinical chemistry · 2018

Performance of high-sensitivity cardiac troponin in the emergency department for myocardial infarction and a composite cardiac outcome across different estimated glomerular filtration rates.

Kavsak Peter A, Worster Andrew, Shortt Colleen, Ma Jinhui, Clayton Natasha, Sherbino Jonathan, Hill Stephen A, McQueen Matthew, Griffith Lauren E, Mehta Shamir R, McRae Andrew D, Devereaux P J

СтатьяМногоцентровое исследованиеНаблюдательное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

Clinicians regularly observe increased high-sensitivity cardiac troponin (hs-cTn) concentrations in patients with low estimated glomerular filtration rate (eGFR). The challenge is to differentiate acute coronary syndrome (ACS) from increased hs-cTn results across a range of eGFR. The objective of this study was to determined the optimal hs-cTn concentrations for acute myocardial infarction (MI) and a composite cardiovascular outcome across different eGFR ranges and to assess the utility of a low hs-cTn cutoff to rule-out events.

METHODS

We undertook an observational study in the emergency department of patients (n = 1212) with symptoms suggestive of ACS who had an eGFR and at least one Roche hs-cTnT and one Abbott hs-cTnI result. The 7-day outcomes were MI or a composite of MI, unstable angina, congestive heart failure, serious ventricular cardiac arrhythmia, or death. The maximum hs-cTn concentration was assessed across different eGFR ranges (<30,30-59,60-89,≥90 ml/min/1.73m2) by spearman correlation, ROC-curve analyses, and sensitivity and negative predictive value (NPV) for the proposed rule-out hs-cTn cutoffs (hs-cTnI<5 ng/l and hs-cTnT<6 ng/l) for the outcomes.

RESULTS

Both hs-cTnI and hs-cTnT concentrations were negatively correlated with eGFR. The lower the eGFR, the lower the AUC and the higher the optimal hs-cTn cutoffs for both MI and the composite outcome. The highest combined sensitivity (100%), NPV (100%) and proportion of low-risk for MI (45% of group) was observed for patients with hs-cTnT<6 ng/l with an eGFR≥90.

CONCLUSION

The test performance for hs-cTn for diagnosing or ruling-out an acute cardiac event varies per the eGFR. Accurate risk stratification requires knowledge of the eGFR.

Для цитирования: Kavsak Peter A, Worster Andrew, Shortt Colleen, Ma Jinhui, Clayton Natasha, Sherbino Jonathan, Hill Stephen A, McQueen Matthew, Griffith Lauren E, Mehta Shamir R, McRae Andrew D, Devereaux P J. Performance of high-sensitivity cardiac troponin in the emergency department for myocardial infarction and a composite cardiac outcome across different estimated glomerular filtration rates.. Clinica chimica acta; international journal of clinical chemistry. 2018. DOI: 10.1016/j.cca.2018.01.034.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.