MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/j.1475-1313.2012.00904.x

Медицинская библиотека · Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists) · 2012

Optical quality for keratoconic eyes with conventional RGP lens and simulated, customised contact lens corrections: a comparison.

Jinabhai Amit, Neil Charman W, O'Donnell Clare, Radhakrishnan Hema

Сравнительное исследованиеСтатьяПоддержка правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To compare monochromatic aberrations of keratoconic eyes when uncorrected, corrected with spherically-powered RGP (rigid gas-permeable) contact lenses and corrected using simulations of customised soft contact lenses for different magnitudes of rotation (up to 15°) and translation (up to 1mm) from their ideal position.

METHODS

The ocular aberrations of examples of mild, moderate and severe keratoconic eyes were measured when uncorrected and when wearing their habitual RGP lenses. Residual aberrations and point-spread functions of each eye were simulated using an ideal, customised soft contact lens (designed to neutralise higher-order aberrations, HOA) were calculated as a function of the angle of rotation of the lens from its ideal orientation, and its horizontal and vertical translation.

RESULTS

In agreement with the results of other authors, the RGP lenses markedly reduced both lower-order aberrations and HOA for all three patients. When compared with the RGP lens corrections, the customised lens simulations only provided optical improvements if their movements were constrained within limits which appear to be difficult to achieve with current technologies.

CONCLUSIONS

At the present time, customised contact lens corrections appear likely to offer, at best, only minor optical improvements over RGP lenses for patients with keratoconus. If made in soft materials, however, these lenses may be preferred by patients in term of comfort.

Для цитирования: Jinabhai Amit, Neil Charman W, O'Donnell Clare, Radhakrishnan Hema. Optical quality for keratoconic eyes with conventional RGP lens and simulated, customised contact lens corrections: a comparison.. Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists). 2012. DOI: 10.1111/j.1475-1313.2012.00904.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.