DOI 10.1016/j.jcrs.2011.08.041
Higher-order aberrations after corneal collagen crosslinking for keratoconus and corneal ectasia.
Аннотация
PURPOSE: To determine changes in higher-order aberrations (HOAs) after corneal collagen crosslinking (CXL).
SETTING
Cornea and refractive surgery practice.
DESIGN
Prospective randomized controlled clinical trial.
METHODS
Corneal and ocular HOAs were measured and analyzed using the Pentacam device and Ladarwave aberrometer, respectively, at baseline and 12 months after CXL.
RESULTS
Ninety-six eyes (64 keratoconus, 32 ectasia) of 73 patients had CXL. A fellow-eye control group comprised 42 eyes. The mean preoperative total anterior corneal HOAs, total coma, 3rd-order coma, and vertical coma were 4.68 μm ± 2.33 (SD), 4.40 ± 2.32 μm, 4.36 ± 2.30 μm, and 4.04 ± 2.27 μm, respectively. At 1 year, the mean values decreased significantly to 4.27 ± 2.25 μm, 4.01 ± 2.29 μm, 3.96 ± 2.27 μm, and 3.66 ± 2.22 μm, respectively (all P<.001). There were no significant changes in posterior corneal HOAs. The mean preoperative total ocular HOAs, total coma, 3rd-order coma, trefoil, and spherical aberration were 2.80 ± 1.0 μm, 2.60 ± 1.03 μm, 2.57 ± 1.03 μm, 0.98 ± 0.46 μm, and 0.90 ± 0.42 μm, respectively. At 1 year, the mean values decreased significantly to 2.59 ± 1.06 μm, 2.42 ± 1.07 μm, 2.39 ± 1.07 μm, 0.88 ± 0.49 μm, and 0.83 ± 0.38 μm, respectively (all P=.01). After CXL, HOAs were significantly improved compared with the control group. Changes in HOAs were not statistically associated with an improvement in visual acuity or most subjective visual symptoms, however.
CONCLUSION
Corneal and ocular HOAs decreased after CXL, suggesting an improvement in corneal shape.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.