MedElevator Войти в исследования
← Поиск публикаций

DOI 10.4070/kcj.2017.0094

Медицинская библиотека · Korean circulation journal · 2017

Clinical and Angiographic Outcomes of the First Korean-made Sirolimus-Eluting Coronary Stent with Abluminal Bioresorbable Polymer.

Yang Hyoung Mo, Seo Kyoung Woo, Yoon Junghan, Kim Hyo Soo, Chang Kiyuk, Lim Hong Seok, Choi Byoung Joo, Choi So Yeon, Yoon Myeong Ho, Lee Seung Hwan, Ahn Sung Gyun, Youn Young Jin, Lee Jun Won, Koo Bon Kwon, Park Kyung Woo, Yang Han Mo, Han Jung Kyu, Seung Ki Bae, Chung Wook Sung, Kim Pum Joon, Koh Yoon Seok, Park Hun Jun, Tahk Seung Jea

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND AND

OBJECTIVES

This trial evaluated the safety and efficacy of the Genoss drug-eluting coronary stent.

METHODS

This study was a prospective, multicenter, randomized trial with a 1:1 ratio of Genoss drug-eluting stent (DES)™ and Promus Element™. Inclusion criteria were the presence of stable angina, unstable angina, or silent ischemia. Angiographic inclusion criteria were de novo coronary stenotic lesion with diameter stenosis >50%, reference vessel diameter of 2.5-4.0 mm, and lesion length ≤40 mm. The primary endpoint was in-stent late lumen loss at 9-month quantitative coronary angiography follow-up. Secondary endpoints were in-segment late lumen loss, binary restenosis rate, death, myocardial infarction (MI), target lesion revascularization (TLR), target vessel revascularization (TVR), and stent thrombosis during 9 months of follow-up.

RESULTS

We enrolled 38 patients for the Genoss DES™ group and 39 patients for the Promus Element™ group. In-stent late lumen loss at 9 months was not significantly different between the 2 groups (0.11±0.25 vs. 0.16±0.43 mm, p=0.567). There was no MI or stent thrombosis in either group. The rates of death (2.6% vs. 0%, p=0.494), TLR (2.6% vs. 2.6%, p=1.000), and TVR (7.9% vs. 2.6%, p=0.358) at 9 months were not significantly different.

CONCLUSION

This first-in-patient study of the Genoss DES™ stent showed excellent angiographic outcomes for in-stent late lumen loss and major adverse cardiac events over a 9-month follow-up.

Для цитирования: Yang Hyoung Mo, Seo Kyoung Woo, Yoon Junghan, Kim Hyo Soo, Chang Kiyuk, Lim Hong Seok, Choi Byoung Joo, Choi So Yeon, Yoon Myeong Ho, Lee Seung Hwan, Ahn Sung Gyun, Youn Young Jin, Lee Jun Won, Koo Bon Kwon, Park Kyung Woo, Yang Han Mo, Han Jung Kyu, Seung Ki Bae, Chung Wook Sung, Kim Pum Joon, Koh Yoon Seok, Park Hun Jun, Tahk Seung Jea. Clinical and Angiographic Outcomes of the First Korean-made Sirolimus-Eluting Coronary Stent with Abluminal Bioresorbable Polymer.. Korean circulation journal. 2017. DOI: 10.4070/kcj.2017.0094.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.