Bilateral ring-shaped intrastromal opacities after corneal cross-linking for keratoconus.

Camesasca Fabrizio I, Vinciguerra Paolo, Seiler Theo

Клинический случайСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To report a case of bilateral, ring-shaped, intrastromal corneal opacities after corneal cross-linking (CXL) for progressive keratoconus.

METHODS

A 21-year-old man with bilateral, progressive keratoconus underwent CXL with riboflavin 0.1% and ultraviolet A (UVA) light in the right eye and, 6 months later, in the left eye.

RESULTS

One day after CXL, the right eye showed a sharply demarcated white ring in the corneal periphery. The ring involved the superficial stroma at 2 mm from the limbus, extended from 1 to 11 o'clock, and was 1.5-mm wide. Corneal topography showed marked central flattening. Six months after treatment, a residual, faint, ring-shaped opacity remained, with a decrease in corneal ectasia. Cross-linking was then performed in the left eye. Different ultraviolet devices were used in the two eyes. On postoperative day 1, the left eye also showed a white ring of stromal opacity. Scheimpflug imaging showed corneal stromal contraction in the zone of whitening. At final examination, >1 year after surgery, corrected visual acuity was 0.00 logMAR with cylinder of 2.00 diopters in both eyes.

CONCLUSIONS

The bilateral intrastromal corneal changes were innocuous in the long-term, with preservation of good visual acuity and successful stabilization of progressive keratoconus.

Для цитирования: Camesasca Fabrizio I, Vinciguerra Paolo, Seiler Theo. Bilateral ring-shaped intrastromal opacities after corneal cross-linking for keratoconus.. Journal of refractive surgery (Thorofare, N.J. : 1995). 2011. DOI: 10.3928/1081597x-20110812-02.