Best Practices in GC-MS and GC × GC-MS-Based Metabolomics and Volatile Analyses: An International Survey.

Giebelhaus Ryland T, Herold Michael, Harynuk James J, Alonso David E, Amer Bashar, Broeckling Corey D, Charisiadis Pantelis, Cumeras Raquel, de la Mata A Paulina, Dunn Warwick, Franchina Flavio A, Gika Helen, Kirwan Jennifer A, Muti Isabella H, Najdekr Lukáš, Pujos-Guillot Estelle, Stefanuto Pierre-Hugues, Steininger-Mairinger Teresa, Thakker Alpesh, Fiehn Oliver

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

Standardized quality assurance and quality control (QA/QC) practices are essential for reproducible GC-MS metabolomics, yet systematic documentation of current laboratory practices has been lacking. Here, as part of the Metabolomic Quality Assurance and Quality Control Consortium (mQACC), we surveyed 85 laboratories from 27 countries to characterize QA/QC implementation and establish evidence-based recommendations. Respondents represented diverse applications, with 79% performing untargeted analysis, 60% conducting targeted analyses, and 44% conducting both. While single column chromatography is clearly the norm, 24% of the participants used multidimensional chromatography to improve the separation of complex mixtures. Electron ionization with autotuning dominated >95% of the respondents, but more than 30% of the laboratories at least occasionally also used chemical ionization. While most laboratories used low-resolution mass spectrometers, almost half of the laboratories also performed GC-MS analyses on high-resolution QTOF or Orbitrap instruments. A strong consensus emerged on critical QA/QC practices: >90% of laboratories use internal standards for quality control, perform regular leak checks, and maintain injector systems through routine component replacement, spanning column (exchange/cuts), liners, syringes, and septa. Routine monitoring (>50%) involves method blanks, peak shape assessments, and systematic evaluation of intensity drifts, carryovers, and contamination. Retention indices coupled with mass spectral library matching served as the primary annotation approach (60%). Overall, a consensus of best practices in QA/QC and reporting emerged, providing evidence-based recommendations for high-quality GC-MS metabolomics.

Для цитирования: Giebelhaus Ryland T, Herold Michael, Harynuk James J, Alonso David E, Amer Bashar, Broeckling Corey D, Charisiadis Pantelis, Cumeras Raquel, de la Mata A Paulina, Dunn Warwick, Franchina Flavio A, Gika Helen, Kirwan Jennifer A, Muti Isabella H, Najdekr Lukáš, Pujos-Guillot Estelle, Stefanuto Pierre-Hugues, Steininger-Mairinger Teresa, Thakker Alpesh, Fiehn Oliver. Best Practices in GC-MS and GC × GC-MS-Based Metabolomics and Volatile Analyses: An International Survey.. Analytical chemistry. 2026. DOI: 10.1021/acs.analchem.5c06918.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.