DOI 10.1097/ico.0b013e31820009d4
Cataract surgery with toric intraocular lens implantation in keratoconus: a case report.
Аннотация
PURPOSE: We report 2 cases in which cataract extraction with a foldable acrylic toric intraocular lens (IOL) implantation was used to correct (irregular) corneal astigmatism in patients with keratoconus and cataract.
METHODS
Case 1 was a 78-year-old man with cataract and keratoconus in the left eye. He underwent phacoemulsification with a toric IOL [Acrysof SN60T9; cylinder power: 6.0 diopters (D)] implantation. Case 2 was a 64-year-old woman with bilateral cataract and keratoconus. She underwent phacoemulsification with toric IOL implantation in the right (Acrysof SN60T9; cylinder power: 6.0 D) and left eyes (Acrysof SN60T5; cylinder power: 3.0 D). Postoperative follow-up in both cases was 6 months.
RESULTS
In case 1, the uncorrected visual acuity increased from 20/400 to 20/50. The refractive cylinder decreased from -6.0 to -1.5 D, which is a reduction of 75%. In case 2, the uncorrected visual acuity increased from 20/400 to 20/130 in the right eye and from 20/400 to 20/30 in the left eye. Refractive astigmatism decreased by 70% in both eyes. No IOL misalignment or other complications occurred.
CONCLUSIONS
Cataract extraction with toric IOL implantation can be used to correct (irregular) astigmatism and to improve visual functioning in patients with mild to moderate amounts of stable keratoconus and cataract.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.