The intrastromal corneal ring in penetrating keratoplasty-long-term results of a prospective randomized study.

Birnbaum Florian, Schwartzkopff Johannes, Böhringer Daniel, Reinhard Thomas

СтатьяРандомизированное исследованиеПеревод пока не подготовлен

Аннотация

PURPOSE: Postoperative astigmatism after penetrating keratoplasty is a major problem in corneal transplantation. The purpose of this prospective randomized study was to evaluate the efficacy and safety of an intrastromal corneal ring after penetrating keratoplasty.

METHODS

Twenty patients were included, 10 of whom received an intracorneal ring (group 1) and 10 who did not (group 2, control group). Astigmatism in Orbscan corneal topography, occurrence of immune reactions, and occurrence of side effects were this study's main outcome criteria.

RESULTS

Mean follow-up time was 27.6 ± 5.3 months. Mean astigmatism (Orbscan) was 4.4 diopters in group 1 and 4.4 diopters in group 2 (P = 0.695). Spontaneous suture rupture occurred in 5 patients with corneal ring but in none of those in the control group. We observed 3 immune reactions in 3 patients with corneal ring, whereas group 2 experienced no rejection (P < 0.05). Endothelial cell loss was 15.1% in the group with the ring and 8.7% in the control group. That difference was not statistically significant (P = 0.146).

CONCLUSIONS

The use of the intrastromal corneal ring after penetrating keratoplasty caused no reduction in postoperative astigmatism. However, its use was statistically significantly associated with adverse events.

Для цитирования: Birnbaum Florian, Schwartzkopff Johannes, Böhringer Daniel, Reinhard Thomas. The intrastromal corneal ring in penetrating keratoplasty-long-term results of a prospective randomized study.. Cornea. 2011. DOI: 10.1097/ico.0b013e318206caa9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.