MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/bot.0b013e318180db09

Медицинская библиотека · Journal of orthopaedic trauma · 2008

Volar plate fixation of AO type C2 and C3 distal radius fractures, a single-center study of 55 patients.

Gruber Gerald, Gruber Karl, Giessauf Christian, Clar Heimo, Zacherl Max, Fuerst Florentine, Bernhardt Gerwin A

Клиническое исследованиеСтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

We hypothesized that volar locked plate fixation of AO type C2 or C3 fractures could effectively maintain radiographic reduction as shown by comparison of immediate postoperative alignment and that seen after more than 12 months' follow-up.

DESIGN

Prospective cohort study.

SETTING

Level II trauma center located in a suburban area.

PATIENTS: Fifty-five adult patients with intra-articular fractures of the distal radius.

INTERVENTION: Open reduction and internal fixation with a locked volar plate and screws.

MAIN OUTCOME MEASUREMENTS: Volar tilt, radial inclination, radial length, and articular incongruity were radiologically assessed immediately postoperatively and at the time of final follow-up (mean follow-up: 29 +/- 7 months).

RESULTS

At final radiographic examination, the average loss of volar tilt was 1.9 +/- 3.3 degrees (P < 0.001) and the average loss of radial inclination was 1.4 +/- 2.8 degrees (P < 0.001). Four patients had more than 5 degrees loss of radial inclination (7.8%), and 22 patients (43.1%) had more than 5 degrees loss of volar tilt. Radial shortening was not statistically significant (P > 0.05).

CONCLUSIONS

The treatment of intra-articular fractures of the distal radius with a volar locked plating system is associated with a small but statistically significant loss of volar tilt and radial inclination upon comparison of immediate postoperative alignment with that seen after more than 12 months' follow-up.

Для цитирования: Gruber Gerald, Gruber Karl, Giessauf Christian, Clar Heimo, Zacherl Max, Fuerst Florentine, Bernhardt Gerwin A. Volar plate fixation of AO type C2 and C3 distal radius fractures, a single-center study of 55 patients.. Journal of orthopaedic trauma. 2008. DOI: 10.1097/bot.0b013e318180db09.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.