JSLS : Journal of the Society of Laparoendoscopic Surgeons · 2016
Use of Barbed Sutures in Laparoscopic Gastrointestinal Single-Layer Sutures.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Tsukada Tomoya, Kaji Masahide, Kinoshita Jun, Shimizu Koichi
Аннотация
BACKGROUND AND OBJECTIVES: Laparoscopic anastomotic methods are not commonly used because of the cumbersome laparoscopic intracorporeal sutures and tying involved. The barbed suture is one of the various devices developed to simplify the placement of intracorporeal sutures. However, barbed sutures are not commonly used during reconstruction after radical gastrectomy in cancer patients or for single-layer entire-thickness running suturing for intestinal anastomoses. We describe the procedure for using barbed sutures and report on the short-term surgical outcomes.
METHODS: Between August 2012 and March 2014, 15-cm-long barbed sutures (V-Loc 180; Covidien, Mansfield, MA, USA) were used for laparoscopic intestinal anastomoses, including intestinal hole closure for esophagojejunal and gastrojejunal anastomoses after mechanical anastomoses and gastric wall closure after partial resection.
RESULTS: In total, 38 patients underwent 40 laparoscopic anastomoses (esophagojejunostomies, 26; gastrojejunostomies, 7; and simple closure of gastric defect, 7); no cases required conversion to open surgery. Two cases exhibited positive air leak test results during surgery (1 case of esophagojejunostomy and 1 case of simple closure of gastric defect). Two cases of intestinal obstruction were noted; of those, one patient with postoperative intestinal paresis (grade II) was managed conservatively, and the other underwent repeat laparoscopic surgery (grade IIIb) for internal herniation unrelated to V-Loc use. No postoperative complications at the anastomosis site and no surgery-related deaths were noted.
CONCLUSION: Single-layer entire-thickness running suturing with the V-Loc 180 barbed suture after stapled side-to-side intestinal anastomosis was found to be safe and feasible in the reported cases.
METHODS: Between August 2012 and March 2014, 15-cm-long barbed sutures (V-Loc 180; Covidien, Mansfield, MA, USA) were used for laparoscopic intestinal anastomoses, including intestinal hole closure for esophagojejunal and gastrojejunal anastomoses after mechanical anastomoses and gastric wall closure after partial resection.
RESULTS: In total, 38 patients underwent 40 laparoscopic anastomoses (esophagojejunostomies, 26; gastrojejunostomies, 7; and simple closure of gastric defect, 7); no cases required conversion to open surgery. Two cases exhibited positive air leak test results during surgery (1 case of esophagojejunostomy and 1 case of simple closure of gastric defect). Two cases of intestinal obstruction were noted; of those, one patient with postoperative intestinal paresis (grade II) was managed conservatively, and the other underwent repeat laparoscopic surgery (grade IIIb) for internal herniation unrelated to V-Loc use. No postoperative complications at the anastomosis site and no surgery-related deaths were noted.
CONCLUSION: Single-layer entire-thickness running suturing with the V-Loc 180 barbed suture after stapled side-to-side intestinal anastomosis was found to be safe and feasible in the reported cases.