Медицинская библиотека · Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2022

Reduction of radiation exposure during transcatheter edge-to-edge mitral valve repair.

Paulus Michael G, Meindl Christine, Hamerle Michael, Schach Christian, Maier Lars S, Debl Kurt, Birner Christoph, Unsöld Bernhard

СтатьяНаблюдательное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

Transcatheter mitral valve repair is an increasingly used therapy for mitral regurgitation which requires fluoroscopic guidance. Limiting radiation exposure during lengthy procedures is important for both patient and operator safety. This study aimed to investigate radiation dose during contemporary use of MitraClip implantation and the effects of a dose reduction program.

METHODS

A total of 115 patients who underwent MitraClip implantation were prospectively enrolled in a single-center observational study. During the inclusion period, our institution adopted a radiation dose reduction program, comprising lowering of fluoroscopy pulse rate and image target dose. The first 58 patients were treated with conventional fluoroscopy settings, while the following 57 patients underwent the procedure with the newly implemented low dose protocol.

RESULTS

Radiation dose area product significantly decreased after introduction of the low dose protocol (693 [366-1231] vs. 2265 [1517-3914] cGy·cm2 , p < 0.001). After correcting for fluoroscopy time, gender and body mass index, the low dose protocol emerged as a strong negative predictor of radiation dose (p < 0.001), reducing dose area product by 64% (95% confidence interval [57-70]). Device time, device success, and procedural safety did not differ between the normal dose and low dose group. Furthermore, the low dose protocol was not associated with an increased incidence of a combined endpoint consisting of death, repeat intervention, or heart surgery during 12 months follow-up.

CONCLUSION

Reduction of radiation exposure during transcatheter mitral valve repair by 64% is feasible without affecting procedural success or safety.

Для цитирования: Paulus Michael G, Meindl Christine, Hamerle Michael, Schach Christian, Maier Lars S, Debl Kurt, Birner Christoph, Unsöld Bernhard. Reduction of radiation exposure during transcatheter edge-to-edge mitral valve repair.. Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions. 2022. DOI: 10.1002/ccd.30046.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.