MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/23259671241302069

Медицинская библиотека · Orthopaedic journal of sports medicine · 2025

The Primary Stability of Arthroscopic Subscapularis Tendon Repair Depends on the Suture Technique: A Biomechanical Evaluation of 4 Different Repair Techniques.

Nacov Julia A, Kammerlohr Sandra, Staat Manfred, Buess Eduard, Leschinger Tim, Wegmann Kilian, Müller Lars P, Hackl Michael

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Numerous single- and double-row repair techniques with simple and modified stitches have been described for subscapularis tendon tears.

PURPOSE/HYPOTHESIS: This study aimed to uniformly evaluate the influence of 4 different repair techniques on the biomechanical performance of fixation for full-thickness subscapularis tendon tears. It was hypothesized that (1) the 2 modified single-row repair techniques would require more cycles to result in 3- and 5-mm gap formation and have a higher load to failure after cyclic loading than the simple single-row repair technique and (2) the double-row repair technique would also require more cycles to result in 3- and 5-mm gap formation and have a significantly higher load to failure after cyclic loading compared to the simple single-row repair technique.

STUDY

DESIGN

Controlled laboratory study.

METHODS

Full-thickness subscapularis tendon tears were created in 32 fresh-frozen cadaveric shoulders, and the tears were treated in 1 of 4 ways: (1) single-row repair with the mattress stitch, (2) single-row repair with the modified lasso-loop stitch, (3) single-row repair with the modified Mason-Allen stitch, or (4) double-row repair. After repair, specimens were progressively cyclically loaded to 200 N, and the number of cycles to obtain a 3- and 5-mm gap was recorded. After cyclic loading, the specimens were loaded to failure at 500 mm/min, and ultimate failure loads were measured.

RESULTS

There were no significant differences between either of the modified single-row repair techniques and the simple single-row repair technique. Double-row repair withstood significantly more cycles until 3-mm (P < .001) and 5-mm (P = .004) gap formation and had a higher ultimate failure load (P = .015) compared to the simple single-row repair technique, and double-row repair withstood more cycles until 3-mm gap formation (P = .003) compared with single-row repair with the modified lasso-loop stitch. No significant differences were found between double-row repair and single-row repair with the modified Mason-Allen stitch.

CONCLUSION

Findings indicated that (1) there was no significant biomechanical advantage of the modified single-row repair techniques over the simple single-row repair technique and (2) while the double-row repair technique was biomechanically superior to the simple single-row repair technique, there was no significant difference between single-row repair with the modified Mason-Allen stitch and double-row repair.

CLINICAL RELEVANCE: Considering that double-row repair might not be useful in some tears because of the risk of overtensioning, modified single-row repair techniques appear to be an adequate refixation alternative.

Для цитирования: Nacov Julia A, Kammerlohr Sandra, Staat Manfred, Buess Eduard, Leschinger Tim, Wegmann Kilian, Müller Lars P, Hackl Michael. The Primary Stability of Arthroscopic Subscapularis Tendon Repair Depends on the Suture Technique: A Biomechanical Evaluation of 4 Different Repair Techniques.. Orthopaedic journal of sports medicine. 2025. DOI: 10.1177/23259671241302069.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.