Microvascular Coupling in Venous Anastomoses for Head and Neck Reconstruction: A Systematic Review and Meta-Analysis.

Costantino Andrea, Uralov Daniel, Festa Bianca Maria, Pace Gian Marco, Alamoudi Uthman, Haughey Bruce, Iannella Giannicola, Greco Antonio, Magnuson J Scott, De Virgilio Armando

СтатьяМетаанализСистематический обзорПеревод пока не подготовлен

Аннотация

OBJECTIVE

We conducted a systematic review and meta-analysis to compare venous couplers and hand-sewn techniques for venous anastomosis in head and neck reconstruction.

DATA SOURCES: PubMed/MEDLINE and Scopus, databases were searched for relevant publications. Additionally, a manual search was performed in Google Scholar and through reference lists.

REVIEW

METHODS

Retrospective and prospective cohort studies were included. Odds ratios (ORs) and mean differences (MD) were calculated with their 95% confidence intervals (CIs) for each study comparing the 2 groups (coupler vs hand). The inverse variance method was used to combine the effect sizes from the individual studies.

RESULTS

A total of 14,053 patients undergoing 14,270 head and neck free flap reconstructions were included from 52 studies. A total of 6080 flaps were performed using a coupling device for the venous anastomoses, while 8190 flaps were performed with the hand-sewn technique. No significant difference was found for the venous thrombosis rate (OR: 1.06, 95% CI: 0.65-1.72), and reoperation rate (OR: 0.93, 95% CI: 0.51-1.70), but a significantly lower failure rate was measured for the coupler group (OR = 0.34, 95% CI: 0.20-0.58). A nonsignificant lower operative time was found for venous anastomoses (MD: -20.5, 95% CI: -51.7 to 10.7) and total surgery (MD: -23.7, 95% CI: -344.3 to 296.8) for the coupler group.

CONCLUSION

Despite the slight advantages observed with venous couplers, the overall outcomes of both techniques are excellent, and the choice of anastomotic technique should be guided by surgeon preference.

Для цитирования: Costantino Andrea, Uralov Daniel, Festa Bianca Maria, Pace Gian Marco, Alamoudi Uthman, Haughey Bruce, Iannella Giannicola, Greco Antonio, Magnuson J Scott, De Virgilio Armando. Microvascular Coupling in Venous Anastomoses for Head and Neck Reconstruction: A Systematic Review and Meta-Analysis.. Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery. 2025. DOI: 10.1002/ohn.1167.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.