MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jacc.2004.11.057

Медицинская библиотека · Journal of the American College of Cardiology · 2005

Transcatheter radiofrequency ablation of atrial fibrillation in patients with mitral valve prostheses and enlarged atria: safety, feasibility, and efficacy.

Lang Christopher C, Santinelli Vincenzo, Augello Giuseppe, Ferro Amedeo, Gugliotta Filippo, Gulletta Simone, Vicedomini Gabriele, Mesas Cézar, Paglino Gabriele, Sala Simone, Sora Nicoleta, Mazzone Patrizio, Manguso Francesco, Pappone Carlo

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

Few data have been published on transcatheter ablation of atrial fibrillation (AF) in patients with mitral valve prostheses. Thus, we sought to report our experience.

BACKGROUND

Ablation is an effective treatment for AF. Patients with prosthetic mitral valves represent a special group because of an increased risk from the ablation procedure due to the possibility of damage to the prosthetic valve.

METHODS

Between July 2001 and July 2003, 26 patients with mitral valve prostheses (MVP) underwent circumferential pulmonary vein ablation for AF. A matched group of 52 ablated patients without MVP acted as control subjects. After a blanking period of three months, a follow-up of 12 months was considered for MVP patients and controls. Holter recordings were performed in all subjects at 3, 6, and 12 months.

RESULTS

Radiation exposure was higher in the MVP group, with fluoroscopy times of 35.3 +/- 21 min versus 20.9 +/- 15 min in controls. At the end of follow-up, 73% of MVP patients were in sinus rhythm, compared with 75% of controls. Atrial tachycardia occurred in six (23%) MVP patients, requiring repeat ablation in three, and one (2%) control subject, which settled without treatment. One transient ischemic attack and one femoral pseudoaneurysm occurred in the MVP group. No complications occurred in the control group.

CONCLUSIONS

Ablation of AF in patients with MVP is feasible, with outcomes similar to those of standard patients. Complications were higher among MVP patients with a greater radiation exposure and a higher incidence of post-ablation atrial tachycardia.

Для цитирования: Lang Christopher C, Santinelli Vincenzo, Augello Giuseppe, Ferro Amedeo, Gugliotta Filippo, Gulletta Simone, Vicedomini Gabriele, Mesas Cézar, Paglino Gabriele, Sala Simone, Sora Nicoleta, Mazzone Patrizio, Manguso Francesco, Pappone Carlo. Transcatheter radiofrequency ablation of atrial fibrillation in patients with mitral valve prostheses and enlarged atria: safety, feasibility, and efficacy.. Journal of the American College of Cardiology. 2005. DOI: 10.1016/j.jacc.2004.11.057.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.