MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1056/nejmoa0911781

Медицинская библиотека · The New England journal of medicine · 2010

Target ranges of oxygen saturation in extremely preterm infants.

SUPPORT Study Group of the Eunice Kennedy Shriver NICHD Neonatal Research Network, Carlo Waldemar A, Finer Neil N, Walsh Michele C, Rich Wade, Gantz Marie G, Laptook Abbot R, Yoder Bradley A, Faix Roger G, Das Abhik, Poole W Kenneth, Schibler Kurt, Newman Nancy S, Ambalavanan Namasivayam, Frantz Ivan D, Piazza Anthony J, Sánchez Pablo J, Morris Brenda H, Laroia Nirupama, Phelps Dale L, Poindexter Brenda B, Cotten C Michael, Van Meurs Krisa P, Duara Shahnaz, Narendran Vivek, Sood Beena G, O'Shea T Michael, Bell Edward F, Ehrenkranz Richard A, Watterberg Kristi L, Higgins Rosemary D

Сравнительное исследованиеСтатьяМногоцентровое исследованиеРандомизированное исследованиеПоддержка NIH: внешняя программаПеревод пока не подготовлен

Аннотация

BACKGROUND

Previous studies have suggested that the incidence of retinopathy is lower in preterm infants with exposure to reduced levels of oxygenation than in those exposed to higher levels of oxygenation. However, it is unclear what range of oxygen saturation is appropriate to minimize retinopathy without increasing adverse outcomes.

METHODS

We performed a randomized trial with a 2-by-2 factorial design to compare target ranges of oxygen saturation of 85 to 89% or 91 to 95% among 1316 infants who were born between 24 weeks 0 days and 27 weeks 6 days of gestation. The primary outcome was a composite of severe retinopathy of prematurity (defined as the presence of threshold retinopathy, the need for surgical ophthalmologic intervention, or the use of bevacizumab), death before discharge from the hospital, or both. All infants were also randomly assigned to continuous positive airway pressure or intubation and surfactant.

RESULTS

The rates of severe retinopathy or death did not differ significantly between the lower-oxygen-saturation group and the higher-oxygen-saturation group (28.3% and 32.1%, respectively; relative risk with lower oxygen saturation, 0.90; 95% confidence interval [CI], 0.76 to 1.06; P=0.21). Death before discharge occurred more frequently in the lower-oxygen-saturation group (in 19.9% of infants vs. 16.2%; relative risk, 1.27; 95% CI, 1.01 to 1.60; P=0.04), whereas severe retinopathy among survivors occurred less often in this group (8.6% vs. 17.9%; relative risk, 0.52; 95% CI, 0.37 to 0.73; P<0.001). There were no significant differences in the rates of other adverse events.

CONCLUSIONS

A lower target range of oxygenation (85 to 89%), as compared with a higher range (91 to 95%), did not significantly decrease the composite outcome of severe retinopathy or death, but it resulted in an increase in mortality and a substantial decrease in severe retinopathy among survivors. The increase in mortality is a major concern, since a lower target range of oxygen saturation is increasingly being advocated to prevent retinopathy of prematurity. (ClinicalTrials.gov number, NCT00233324.)

Для цитирования: SUPPORT Study Group of the Eunice Kennedy Shriver NICHD Neonatal Research Network, Carlo Waldemar A, Finer Neil N, Walsh Michele C, Rich Wade, Gantz Marie G, Laptook Abbot R, Yoder Bradley A, Faix Roger G, Das Abhik, Poole W Kenneth, Schibler Kurt, Newman Nancy S, Ambalavanan Namasivayam, Frantz Ivan D, Piazza Anthony J, Sánchez Pablo J, Morris Brenda H, Laroia Nirupama, Phelps Dale L, Poindexter Brenda B, Cotten C Michael, Van Meurs Krisa P, Duara Shahnaz, Narendran Vivek, Sood Beena G, O'Shea T Michael, Bell Edward F, Ehrenkranz Richard A, Watterberg Kristi L, Higgins Rosemary D. Target ranges of oxygen saturation in extremely preterm infants.. The New England journal of medicine. 2010. DOI: 10.1056/nejmoa0911781.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.