MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1155/2022/4384196

Медицинская библиотека · BioMed research international · 2022

Rapid Detection of vanA Resistance Gene from E. faecalis Clinical Isolates Using Duplex Loop-Mediated Isothermal Amplification and Triplex PCR Assay.

Azizi Mohsen, Motamedi Hamid, Hossainpour Hadi, Abiri Ramin, Kashef Mahsa, Ahmadi Kamal, Moradi Jale, Alvandi Amirhooshang

СтатьяПеревод пока не подготовлен

Аннотация

Today, the spread of vancomycin-resistant strains isolated from Enterococcus faecalis (E. faecalis) has become a major health concern worldwide. Therefore, it is essential to provide a rapid and sensitive assay for identifying vanA gene for timely and appropriate antimicrobial control of resistant enterococcal infections. For this purpose, a cross-sectional study was performed on different clinical specimens of enterococci from Imam Reza hospital, Kermanshah, Iran. The antimicrobial susceptibility testing was determined by disk diffusion and MIC methods. Triplex-PCR and duplex-LAMP assays were also used to identify vanA E. faecalis resistance gene isolates. The results of this study shown that out of 108 Enterococcus isolates, 86, 18, 2, 1, and one isolates of E. faecalis, E. faecium, E. avium, E. psudoavium, and E. raffinosus were identified, respectively. On the other hand, E. faecalis was confirmed in 87 and 88 isolates using duplex-LAMP and triplex PCR, respectively. The LAMP primer set designed in this study can reliably identify seven distinct regions of the vanA gene, and finally the sensitivity, specificity, and the positive and negative predictive values of LAMP assay were shown to be 94.19%, 72.73%, 76.19%, and 93.10%, respectively. In general, sample processing, isothermal reaction and result reporting were completed using the LAMP assay in 75 minutes. Our findings suggest that LAMP assay has been approved as an alternative to the vancomycin resistance Enterococcus genotype (vanA and vanB) compared to other methods and has the advantage of being rapid, time-consuming, and easy for diagnosis.

Для цитирования: Azizi Mohsen, Motamedi Hamid, Hossainpour Hadi, Abiri Ramin, Kashef Mahsa, Ahmadi Kamal, Moradi Jale, Alvandi Amirhooshang. Rapid Detection of vanA Resistance Gene from E. faecalis Clinical Isolates Using Duplex Loop-Mediated Isothermal Amplification and Triplex PCR Assay.. BioMed research international. 2022. DOI: 10.1155/2022/4384196.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.