MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1053/j.jvca.2025.04.029

Медицинская библиотека · Journal of cardiothoracic and vascular anesthesia · 2025

Effect of Bicuspid or Tricuspid Aortic Valve on Preoperative Coagulation in Patients Scheduled for Thoracic Aortic Surgery.

van Haeren Maite M T, Bozic Caitlin, Eberl Susanne, Hollmann Markus W, Breel Jennifer S, Grewal Nimrat, Driessen Antoine H G, Vlaar Alexander P J, Müller Marcella C A, Hermanns Henning

СтатьяНаблюдательное исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVES

This study aimed to analyze the impact of aortic valve morphology on preoperative coagulation status in patients undergoing elective thoracic aortic surgery. Preoperative ROTEM and conventional coagulation tests of patients with a bicuspid aortic valve (BAV) were compared to those with a tricuspid aortic valve (TAV).

DESIGN

An exploratory prospective observational study.

SETTING

Conducted in a single center.

PARTICIPANTS

The study included 169 patients (63 BAV and 106 TAV).

INTERVENTIONS: None.

MEASUREMENTS AND MAIN

RESULTS

Mann-Whitney U tests were conducted to compare the groups. Regression analysis was performed to evaluate the association between valve morphology and abnormal ROTEM profiles. BAV patients were on average 10 years younger and had a median aortic diameter 5 mm smaller. No significant differences were found in preoperative ROTEM values or coagulation tests between groups, except for higher D-dimers in TAV patients. Sex was a significant confounder, and aortic diameter was a significant mediator. TAV patients required more red blood cell and platelet transfusions, likely due to more preoperative antiplatelet therapy and longer cardiopulmonary bypass times. Mortality and postoperative complications were similar between groups.

CONCLUSIONS

Patients with a BAV have similar preoperative coagulation profiles and postoperative outcomes as TAV patients, based on ROTEM and conventional coagulation tests. While TAV patients required more RBC and platelet transfusions, this is likely due to factors other than valve type. These findings suggest that BAV patients do not need altered coagulation management despite structural differences and endothelial dysfunction.

Для цитирования: van Haeren Maite M T, Bozic Caitlin, Eberl Susanne, Hollmann Markus W, Breel Jennifer S, Grewal Nimrat, Driessen Antoine H G, Vlaar Alexander P J, Müller Marcella C A, Hermanns Henning. Effect of Bicuspid or Tricuspid Aortic Valve on Preoperative Coagulation in Patients Scheduled for Thoracic Aortic Surgery.. Journal of cardiothoracic and vascular anesthesia. 2025. DOI: 10.1053/j.jvca.2025.04.029.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.