MedElevator Войти в исследования
← Поиск публикаций
Медицинская библиотека · The Israel Medical Association journal : IMAJ · 2017

Transcatheter Tricuspid Valve-In-Valve Implantation in Patients with Tricuspid Bioprosthetic Valve Degeneration at High Surgical Risk: A Multicenter Case Series.

Landes Uri, Kerner Arthur, Segev Amit, Danenberg Haim, Shapira Yaron, Finkelstein Ariel, Kornowski Ran

СтатьяМногоцентровое исследованиеПеревод в очереди

Аннотация

BACKGROUND

Transcatheter tricuspid valve-in-valve implantation (TVIV) is an attractive yet under-explored alternative to redo valve surgery.

OBJECTIVES

To report the multicenter TVIV experience in Israel.

METHODS

We approached multiple centers and collected data regarding seven TVIV cases.

RESULTS

The study group comprised seven participants: five females and two males, with a mean age of 63 ± 12 years and EuroSCORE-II 13.6 ± 3.3%. Follow-up ranged from 3 to 21 months (mean 8 ± 6 months). All presented with advanced heart failure. The indication for valve intervention was a predominant tricuspid stenosis in three patients, significant tricuspid regurgitation in one and a mixture in three. Six procedures were conducted via a transfemoral approach and one by transatrial access. The Edwards SAPIENTM XT valve was used in four cases and the SAPIENTM 3 in three. Without pre-stenting/rapid pacing, all participants underwent successful valve implantation. Mean transvalvular gradient decreased from 11 ± 3 mmHg to 6 ± 3 mmHg (P = 0.003) and regurgitation decreased from moderate/severe (in four cases) to none/trace (in six of the seven cases). One patient remained severely symptomatic and died 3.5 months after the implantation. All others achieved a functional capacity improvement and amelioration of symptoms soon after the implantation, which persisted during follow-up.

CONCLUSIONS

TVIV may be a safe and effective strategy to treat carefully selected patients with degenerated bioprosthetic tricuspid valve at high operative risk.

Для цитирования: Landes Uri, Kerner Arthur, Segev Amit, Danenberg Haim, Shapira Yaron, Finkelstein Ariel, Kornowski Ran. Transcatheter Tricuspid Valve-In-Valve Implantation in Patients with Tricuspid Bioprosthetic Valve Degeneration at High Surgical Risk: A Multicenter Case Series.. The Israel Medical Association journal : IMAJ. 2017.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.